Masseter Muscle Volume and Cross-Sectional Area as Risk Factors for Late Mechanical Dental Implant Failure: A Matched Case-Control Study.
Hee-Sun Choi, Eun-Chong Lee, Eun-Kyoung Pang
Department of Periodontology, Ewha Womans University Mokdong Hospital, Seoul, Republic of Korea.
Key points
From the paper's conclusion- Greater masseter muscle volume and CSA were significantly associated with late mechanical implant failure in this matched case-control study. The proposed cut-off values may provide preliminary reference values for risk stratification. However, these findings should be regarded as exploratory and require prospective validation in independent cohorts before routine clinical implementation.
Abstract
OBJECTIVES: This study aimed to investigate whether three-dimensional (3D) masseter muscle morphology-volume and cross-sectional area (CSA)-is associated with the risk of late mechanical dental implant failure and to derive preliminary cut-off values for risk stratification. MATERIAL AND METHODS: This 1:4 matched case-control study investigated 23 cases of late mechanical failure (fixture fracture, screw fracture, or abutment fracture) and 92 successful controls. Participants were matched by gender, age (±10 years), anatomical location, and maintenance period (±2 years). Masseter morphology was quantified using the 3D reconstruction of the cone-beam computed tomography (CBCT) data. Independent risk factors were determined using a multivariable generalized estimating equation model adjusting for potential confounders. RESULTS: Increased masseter muscle bulk was significantly associated with mechanical failure (p < 0.001). The odds of mechanical failure increased by 1.24-fold per 1000 mm3 increase in masseter volume and by 1.11-fold per 10 mm2 increase in CSA. ROC analysis demonstrated AUCs of 0.846 for masseter volume and 0.871 for CSA. The maximum-Youden thresholds were 31,272.56 mm3 for volume and 691.30 mm2 for CSA, with sensitivities of 86.96% and 82.61% and specificities of 77.17% and 79.35%, respectively. Internal bootstrap validation yielded AUC 95% confidence intervals of 0.751-0.931 and 0.767-0.951, respectively. CONCLUSIONS: Greater masseter muscle volume and CSA were significantly associated with late mechanical implant failure in this matched case-control study. The proposed cut-off values may provide preliminary reference values for risk stratification. However, these findings should be regarded as exploratory and require prospective validation in independent cohorts before routine clinical implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Low pectoralis major muscle mass predicts the risk of post-surgical bleeding after mastectomy in patients with breast cancer.Breast cancer research and treatment · 2026
- Five- to Nine-Year Clinical and Radiographic Performance of Morse-Tapered Hybrid Dental Implants: A Retrospective Observational Study.Dentistry journal · 2026
- Does Masseter Muscle Hypertrophy Affect the Etiology and Localization of Parotid Duct Stones?Laryngoscope investigative otolaryngology · 2026
- Association of posterior occlusal support with ultrasonographic characteristics of the masseter muscle: a prospective single-center study.BMC oral health · 2026
- MRI-based anatomical and biomechanical characterization of the human masticatory muscles.Frontiers in bioengineering and biotechnology · 2026
- Lateral pterygoid muscle volume in temporomandibular joint pathologies necessitating alloplastic replacement: is reattachment necessary in every case? A retrospective computed tomography segmentation study.International journal of oral and maxillofacial surgery · 2026