科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ BJU international2026-08-13

Real-time artificial intelligence-based anatomy recognition in single-port transvesical enucleation of the prostate.

Luca A Morgantini, Laura Cruciani, Andrea Calzolai Lettieri, Fabio M Valenzi, Valerio Santarelli, Flavia Tamborino, Alexandru Turcan, Filippo Carletti, Giovanni Lughezzani, Marco Paciotti, Elena De Momi, Nicolò M Buffi, Simone Crivellaro

一句话结论 · In one sentence

This pilot study demonstrates the potential utility of AI to provide intraoperative anatomical guidance during STEP, establishing a foundation for future clinical integration and performance optimization.

原始摘要(英文原文)· Original abstract
OBJECTIVES: To evaluate the feasibility and accuracy of an artificial intelligence (AI) model to assist surgeons through automated real-time detection and segmentation of key anatomical structures during robot-assisted single-port transvesical enucleation of the prostate (STEP). PATIENTS AND METHODS: This retrospective single-centre study utilised surgical videos from patients undergoing single-port robot-assisted transvesical prostate enucleation performed by a single expert surgeon. Selected frames extracted from these surgical videos were manually annotated to identify anatomical landmarks during the key step of the procedure. The structures annotated were the bladder neck, prostatic adenoma, and the peripheral zone. A convolutional neural network based on the You Only Look Once version 11 architecture was trained using these annotated frames. Model performance was quantitatively assessed through recall, precision, F1-score, Intersection over Union, Dice Similarity Coefficient, and mean average precision (AP). Real-time performance was assessed qualitatively through visual inspection and confirmed quantitatively by measuring frame inference speeds. RESULTS: The study included 611 annotated frames derived from 37 surgical videos. The model demonstrated strong detection performance, with class-specific F1-scores of 0.88 (adenoma), 0.69 (bladder neck), and 0.70 (peripheral zone). Segmentation accuracy, measured by Dice Similarity Coefficient, resulted in adenoma: 0.86; bladder neck: 0.83; peripheral zone: 0.82. Mean AP across all anatomical classes was 0.43. The model consistently operated at >60 frames/s, confirming real-time applicability without perceptible lag. CONCLUSIONS: This pilot study demonstrates the potential utility of AI to provide intraoperative anatomical guidance during STEP, establishing a foundation for future clinical integration and performance optimization.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Real-time artificial intelligence-based anatomy recognition in single-port transvesical enucleation of the prostate. — 科研速览 Science Skim