British journal of haematology

Multimodal deep learning for myelodysplastic neoplasm screening: Integrating annotation-free digital imaging and blood count parameters.

Maxence Bauvais, Alexandre Merasli, Cédric De Almeida Braga, Emmanuelle Rault, Amélie Foucault, Noémie Ravalet, Olivier Hérault, Anna Raimbault,

Service d'Hématologie Biologique, Centre Hospitalier Universitaire de Nantes, Nantes, France. · Service d'Hématologie Biologique, Centre Hospitalier Universitaire de Tours, Tours, France.

Computational · n=208

Key points

From the paper's conclusion
  • More importantly, the multimodal MVNet-MM did better than both unimodal methods areas under the curve (AUC = 0.87, accuracy = 83%).

Abstract

Myelodysplastic neoplasms (MDS) are suspected based on complete blood counts (CBC) and cell morphology but, for the latter, suffer from interoperator variability. Deep learning methods could help decrease these inconsistencies but often require expert annotation of large cell numbers. In this multicentric retrospective study, 208 patients were enrolled but 8 were excluded because fewer than 32 polymorphonuclear neutrophils (PMN) images were available. Thereby, an end-to-end deep learning framework was developed to (i) make predictions without cell annotation, (ii) globally extract dysplastic image features from sets of patient cells, (iii) enhance diagnostic accuracy of existing MDS-CBC scores at the screening stage and (iv) classify cytopenic patients as suffering from MDS or not. A multiview network integrated multimodal information (MVNet-MM), based on CBC parameters and annotation-free PMN. PMN images from patients with MDS (n = 78) or cytopenic controls (n = 80) were pooled from three University Hospital Centres for training and internal validation. An external test cohort (n = 42) including 14 patients with MDS and 28 controls was used for performance evaluation. The unimodal image-based approach performed better and classified patients differently than the MDS-CBC score in some cases. More importantly, the multimodal MVNet-MM did better than both unimodal methods areas under the curve (AUC = 0.87, accuracy = 83%). This model, which does not require cell-by-cell annotation, shows promising perspectives to improve MDS detection at the CBC/morphology step.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Multimodal deep learning for myelodysplastic neoplasm screening: Integrating annotation-free digital imaging and blood count parameters — Science Skim