Asian journal of endoscopic surgery

Feasibility and Safety of PuraStat for Oozing-Type Bleeding During Laparoscopic Hepatectomy: A Prospective Exploratory Study (ASTERIA Study).

Ryo Ashida, Teiichi Sugiura, Katsuhisa Ohgi, Mihoko Yamada, Yoshiyasu Kato, Shimpei Otsuka, Hideyuki Dei, Katsuhiko Uesaka

Division of Hepato-Biliary-Pancreatic Surgery, Shizuoka Cancer Center, Shizuoka, Japan.

Observational · n=20

Key points

From the paper's conclusion
  • PuraStat was feasible and safe for achieving rapid hemostasis in selected oozing-type bleeding during laparoscopic hepatectomy. Its synthetic composition, rapid action, and laparoscopic compatibility make it a promising hemostatic adjunct for minimally invasive hepatic surgery. While rapid hemostasis was achieved in low-grade oozing-type bleeding, further studies are warranted to assess its role in more complex hemorrhagic scenarios.

Abstract

INTRODUCTION: Achieving rapid and reliable hemostasis is critical in laparoscopic hepatectomy, in which limited maneuverability and visualization present unique challenges. PuraStat (3-D Matrix Ltd., Tokyo, Japan), a fully synthetic self-assembling peptide hydrogel, offers a novel approach to hemostasis; however, its utility in hepatic surgery remains underexplored. METHODS: This prospective, single-center exploratory study evaluated the feasibility and safety of PuraStat in controlling oozing from the liver transection surface during laparoscopic hepatectomy. The primary endpoint was successful hemostasis within 3 min after the application of PuraStat. If bleeding persisted longer than 10 min, additional interventions were used, and the case was considered a failure. Patients with spurting bleeding were excluded from this study. RESULTS: Twenty-one patients provided informed consent; one patient was excluded intraoperatively because of arterial spurting bleeding, and 20 patients treated with PuraStat were included in the analysis. The median hemostasis time was 42 s, and the median preparation time for PuraStat before application was 89 s. Hemostasis was achieved within 3 min in 95% of cases using a median volume of just 1.0 mL. No intraoperative complications or postoperative re-bleeding events were observed. One patient developed Clavien-Dindo Grade IIIa bile leakage unrelated to the use of PuraStat. CONCLUSION: PuraStat was feasible and safe for achieving rapid hemostasis in selected oozing-type bleeding during laparoscopic hepatectomy. Its synthetic composition, rapid action, and laparoscopic compatibility make it a promising hemostatic adjunct for minimally invasive hepatic surgery. While rapid hemostasis was achieved in low-grade oozing-type bleeding, further studies are warranted to assess its role in more complex hemorrhagic scenarios.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Feasibility and Safety of PuraStat for Oozing-Type Bleeding During Laparoscopic Hepatectomy: A Prospective Exploratory Study (ASTERIA Study) — Science Skim