Key points
From the paper's conclusion- AI agreed with expert review in about three-quarters of evaluations but provided a guideline-compliant interpretation in less than half; a pragmatic approach raised yield to 70% at the same agreement. The AI withheld classifications that experts could reach; its validated scope covers only part of what ED echocardiography must address, and reports did not mark unassessed parameters. This study reports agreement, not accuracy. For now, human expert review of AI reports is required.
Abstract
OBJECTIVE: To assess the agreement between artificial intelligence (AI) interpretation and expert emergency physician sonologist review of echocardiograms performed in the Emergency Department (ED). METHODS: Retrospective multicentre agreement study in four Australian EDs. A total of 195 echocardiograms (2016-2023) underwent three-stage adjudicated human expert review. Human reports were compared with us2.ai reports. Agreement across 10 validated parameters was reported as percentage exact match with 95% confidence intervals and kappa under two pre-specified tiers: Guideline Compliant (GC; ASE/EACVI multi-view criteria) and Pragmatic (PR; any available measurement). Reference standard reliability was quantified. RESULTS: Pooled agreement was 76% at both tiers (GC n = 875; PR n = 1323); AI returned an interpretation in 46% of evaluations at GC and 70% at PR. Four structural parameters reached 78%-87%: right atrial size 87% (κ = 0.62), right ventricular (RV) contractility 83% (κ = 0.42), left ventricular (LV) size 83% (κ = 0.52) and RV size 78% (κ = 0.37). Binary LV systolic agreement was 79% GC and 83% PR. Expert reviewers agreed on 85% of interpretations. Pericardial effusion, aortic regurgitation and mitral stenosis, present in 7%-20% of patients, are not reported in the current us2.ai algorithm. CONCLUSION: AI agreed with expert review in about three-quarters of evaluations but provided a guideline-compliant interpretation in less than half; a pragmatic approach raised yield to 70% at the same agreement. The AI withheld classifications that experts could reach; its validated scope covers only part of what ED echocardiography must address, and reports did not mark unassessed parameters. This study reports agreement, not accuracy. For now, human expert review of AI reports is required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance of AI models in ECG interpretation and risk stratification for major adverse cardiac events in the emergency department.Technology and health care : official journal of the European Society for Engineering and Medicine · 2026
- Artificial Intelligence in Echocardiography: Five Clinical Challenges and a Roadmap Toward Responsible Integration by 2030.Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir · 2026
- Artificial intelligence-assisted ECG interpretation for identification of occlusive myocardial infarction following cardiac arrest: a multi-reader, multi-case studyScientific Reports · 2026
- Artificial Intelligence Across the Echocardiographic Workflow: A Narrative Review for Clinicians.Cureus · 2026
- Artificial intelligence-based automated interpretation of images of electrocardiograms: development and multinational validation of ECG-GPTEuropean Heart Journal - Digital Health · 2026
- Real-world performance of AI-guided focused cardiac ultrasound: feasibility, interpretability, and detection of significant heart diseaseEuropean Heart Journal · 2026