GC / MS determination of gabapentin in human plasma and vitreous humor and its application to forensic samples
Pamela Cabarcos‐Fernández, Inés Sánchez‐Sellero, Iván Álvarez‐Freire, María Jesús Tabernero‐Duque, Ana María Bermejo‐Barrera
Key points
From the paper's conclusion- The GBP plasma /GBP VH ratio ranged from 1.5 to 2.7 (mean, 1.9) when the case with a higher VH concentration was excluded.
Abstract
Gabapentin (GBP) is widely prescribed off‐label, and cases of misuse, abuse, self‐medication, and intentional self‐harm have been reported. This study aimed to develop and validate a simple GC‐MS method for the determination of GBP in plasma and vitreous humor (VH) and to explore the relationship between concentrations in both matrices in postmortem cases. An SPE procedure was evaluated, and the selected cartridge was used with an extraction procedure adapted from a previously published method. Derivatization was not required, resulting in reduced reagent consumption and a shorter analytical procedure. The method was validated according to FDA guidelines. The calibration ranges were 2.5–15.0 μg/mL for plasma and 1.0–10.0 μg/mL for VH. The method was applied to nine postmortem cases. Plasma GBP concentrations in six intoxication cases ranged from 3.26 to 52.76 μg/mL (mean, 16.1 μg/mL), whereas concentrations in cases in which GBP was considered incidental ranged from 2.47 to 11.44 μg/mL (mean, 7.3 μg/mL). Except for one case, VH concentrations were lower than plasma concentrations. The GBP plasma /GBP VH ratio ranged from 1.5 to 2.7 (mean, 1.9) when the case with a higher VH concentration was excluded. The limited number of cases and potential postmortem factors preclude definitive conclusions regarding the relationship between plasma and VH concentrations. Further studies are warranted to assess VH as an alternative matrix when blood is unavailable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cyclization of gabapentinoids as a novel approach for their determination by GC-MS/MS in biological fluids.Journal of chromatography. A · 2026
- Further Extensive Evaluation of GHB-Pentose as a Novel Biomarker for the Extended Detection of GHB Intake/Administration in Forensic Casework.Drug testing and analysis · 2026
- Validation of the Neogen® ELISA Gabapentin Kit for Blood and Urine.Journal of analytical toxicology · 2026
- Gabapentin protects against streptozotocin-induced diabetic retinopathy in rats: histological, immunohistochemical and ultrastructural study.Ultrastructural pathology · 2026
- First Spectrofluorimetric Determination of Mirogabalin in Biological Fluids: A Validated Hantzsch Derivatization Strategy With Full NMR Structural Confirmation.Luminescence : the journal of biological and chemical luminescence · 2026
- Analytical determination of muscimol in post-mortem blood in a case of polydrug user.Forensic science international · 2026