A 240-Element Matrix Probe With Aberration Mask for 4-D Carotid Artery Computational Ultrasound Imaging.
Yuyang Hu, Michael Brown, Didem Dogan, Mahe Bulot, Maxime Cheppe, Guillaume Ferin, Geert Leus, Antonius F W van der Steen,
Key points
From the paper's conclusion- In this work, we present a 3-D cUSi system tailored for CA imaging, consisting of a 240-element matrix probe with a $40 \,\, \times \,\, 24~ {\mathrm {mm}}^{2}$ large aperture and a spatial encoding mask.
Abstract
Three-dimensional ultrasound provides enhanced visualization of the carotid artery (CA) anatomy and volumetric flow, offering improved accuracy for cardiovascular diagnosis and monitoring. However, fully populated matrix transducers with large apertures are complex and costly to implement. Computational ultrasound imaging (cUSi) offers a promising alternative by enabling simplified hardware design through modelbased reconstruction and spatial field encoding. In this work, we present a 3-D cUSi system tailored for CA imaging, consisting of a 240-element matrix probe with a $40 \,\, \times \,\, 24~ {\mathrm {mm}}^{2}$ large aperture and a spatial encoding mask. We describe the system's design, characterization, and image reconstruction. Phantom experiments show that computational reconstruction using matched filtering (MF) significantly improves volumetric image quality over delay-and-sum (DAS), with spatial encoding enhancing lateral resolution at the cost of reduced contrast ratio (CR). Least-squares with QR (LSQR)-based reconstruction was demonstrated to further improve resolution and suppress artifacts. Using both Hadamard and 16-angle plane wave transmission schemes, the system achieved high-resolution images with reasonable contrast, supporting the feasibility of 4-D CA imaging applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accelerated and memory-efficient clutter filtering toward online-compatible ultrasound localization microscopy via compressed-matrix randomized QRD.Ultrasonics · 2026
- Multi-Frame Reconstruction via Clutter Filtering for Computational Contrast-Enhanced Ultrasound Microflow Imaging.Journal of imaging · 2026
- C2-ULM: Data-Efficient ultrasound localization microscopy via coherent prior MAP beamforming for Sparse, compressed receive acquisition.Ultrasonics · 2026
- Three-Dimensional Ultrasound Localization Microscopy Using Hadamard-Encoded Multipulse and 4D Denoising on a 256-Channel System with a 1024-element Matrix Array: A Feasibility Study in Human Kidney Transplants.ArXiv · 2026
- 4D Ultrafast Ultrasound: the next revolution in biomedical imaging.IEEE transactions on ultrasonics · 2026
- 3-D Ultrafast Imaging Using a 3072-Element Matrix Array.IEEE transactions on ultrasonics · 2026