IEEE transactions on terahertz science and technology

Optimized Calibration of Terahertz Polarimetric Imaging Systems Using Imperfect Polarizers for Accurate Jones-Matrix Mapping.

Arash Karimi, Zachery B Harris, M Hassan Arbab

Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794 USA.

Key points

From the paper's conclusion
  • We validated the framework using a rotating x-cut lithium niobate crystal, showing that accounting for WGP leakage removes systematic errors and yields reflection coefficients consistent with the theoretical values.

Abstract

Accurate terahertz (THz) polarimetric imaging requires robust system calibration to recover the Jones matrix of a sample. In this article, we develop a generalized in situ calibration framework for any THz polarimetry system using a rotating wire-grid polarizer (WGP) placed in front of a mirror. The calibrating WGP is modeled as a lossless but leaky element having a frequency-dependent extinction coefficient and phase retardance. We demonstrate the new method using the polarimetric version of the THz PHASR Scanner as a testbed. We derive two equivalent calibration formulations, one of which is based on an orthogonal harmonic-basis formulation that enables a Fourier series interpretation and motivates rotation angles that are uniformly spaced modulo π . The condition numbers of the two alternative matrices are minimized to optimize the performance of the system with respect to the choice of polarizer rotation angles. Using this approach, calibration can be performed with a minimal set of three optimized angles, yielding a relative error of less than 10% compared to a reference calibration with a full set of 18 angles. We validated the framework using a rotating x-cut lithium niobate crystal, showing that accounting for WGP leakage removes systematic errors and yields reflection coefficients consistent with the theoretical values. Finally, we demonstrate accurate polarimetric imaging of two stacked birefringent crystals with unknown principal axes, by mapping Jones matrices via eigendecomposition in agreement with theory. This approach enables faster, more reliable THz polarimetric imaging in field-deployable scenarios and improves calibration accuracy of bench-top systems for material characterization.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Optimized Calibration of Terahertz Polarimetric Imaging Systems Using Imperfect Polarizers for Accurate Jones-Matrix Mapping — Science Skim