Optimized Calibration of Terahertz Polarimetric Imaging Systems Using Imperfect Polarizers for Accurate Jones-Matrix Mapping.
Arash Karimi, Zachery B Harris, M Hassan Arbab
Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794 USA.
Key points
From the paper's conclusion- We validated the framework using a rotating x-cut lithium niobate crystal, showing that accounting for WGP leakage removes systematic errors and yields reflection coefficients consistent with the theoretical values.
Abstract
Accurate terahertz (THz) polarimetric imaging requires robust system calibration to recover the Jones matrix of a sample. In this article, we develop a generalized in situ calibration framework for any THz polarimetry system using a rotating wire-grid polarizer (WGP) placed in front of a mirror. The calibrating WGP is modeled as a lossless but leaky element having a frequency-dependent extinction coefficient and phase retardance. We demonstrate the new method using the polarimetric version of the THz PHASR Scanner as a testbed. We derive two equivalent calibration formulations, one of which is based on an orthogonal harmonic-basis formulation that enables a Fourier series interpretation and motivates rotation angles that are uniformly spaced modulo π . The condition numbers of the two alternative matrices are minimized to optimize the performance of the system with respect to the choice of polarizer rotation angles. Using this approach, calibration can be performed with a minimal set of three optimized angles, yielding a relative error of less than 10% compared to a reference calibration with a full set of 18 angles. We validated the framework using a rotating x-cut lithium niobate crystal, showing that accounting for WGP leakage removes systematic errors and yields reflection coefficients consistent with the theoretical values. Finally, we demonstrate accurate polarimetric imaging of two stacked birefringent crystals with unknown principal axes, by mapping Jones matrices via eigendecomposition in agreement with theory. This approach enables faster, more reliable THz polarimetric imaging in field-deployable scenarios and improves calibration accuracy of bench-top systems for material characterization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Full-field Jones matrix measurement using in-line polarization terahertz digital holography.Optics letters · 2026
- Model-free self-calibration based high-speed spectrally encoded Mueller matrix polarimetry.Optics express · 2026
- Measurement and Calibration Methods for Full-Polarization Characteristics of Radar Targets at Subterahertz FrequenciesIEEE Transactions on Antennas and Propagation · 2026
- Considerations for calibration of Stokes polarimeters.Journal of the Optical Society of America. A, Optics, image science, and vision · 2026
- Polarization-resolved dual-mode near-field terahertz single-pixel imaging.Optics express · 2026
- HWP-synchronous signal induced by misalignment of the sapphire crystal axisarXiv · 2026