Simultaneous Intraoperative eCAP and eABR Recordings During Cochlear Implant Surgery Reveal Complementary Neural Response Characteristics.
F H Schmidt, T Oberhoffner, D Seyring, A-L Saur, R Mlynski, L Zhang
Key points
From the paper's conclusion- Simultaneous intraoperative eCAP and eABR recordings are feasible and yield highly correlated threshold estimates, supporting a shared dependence on stimulus level. Differences in dynamic and temporal parameters indicate complementary sensitivity to auditory pathway function, supporting the value of combined intraoperative assessment.
Abstract
OBJECTIVE: Electrically evoked compound action potentials (eCAP) and electrically evoked auditory brainstem responses (eABR) provide complementary information on peripheral and brainstem-level auditory function in cochlear implant users. Simultaneous recordings may enable efficient intraoperative assessment, but feasibility and intermodal agreement remain insufficiently characterized. METHODS: Twenty adult cochlear implant recipients were investigated intraoperatively using a unified stimulation paradigm with biphasic pulses (80 pps, 500 averages) and an extended stimulation range. eCAP and eABR (Wave V, ej5) responses were recorded simultaneously. Amplitude growth functions (AGF) were modeled using sigmoidal fits to extract threshold (THR), slope, saturation level (SLS), and saturation amplitude (AS). Intermodal correlations and polarity effects were analyzed. RESULTS: eCAP responses were detectable in 75% of cases with the combined eCAP/eABR protocol, compared with 85% using the standard automated eCAP protocol, and eABRs in 65%, with simultaneous recordings in 60%. A strong correlation was found between eCAP and eABR thresholds (R = 0.90, p < 0.001), whereas slope and saturation parameters showed weaker or no correlations. eCAP thresholds and SLS were systematically higher than corresponding eABR measures. Pulse polarity had no effect on AGF-derived parameters, but cathodic-first stimulation resulted in reduced baseline noise and slightly prolonged eABR latencies. CONCLUSION: Simultaneous intraoperative eCAP and eABR recordings are feasible and yield highly correlated threshold estimates, supporting a shared dependence on stimulus level. Differences in dynamic and temporal parameters indicate complementary sensitivity to auditory pathway function, supporting the value of combined intraoperative assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association between ECAP signal artifacts and electrical components from a cochlear implant impedance model.Zeitschrift fur medizinische Physik · 2026
- Age-dependent variation in eCAP measures across cochlear electrode locations: effects of interphase gap in cochlear implant users.Hearing research · 2026
- Electrically evoked compound action potentials in adult and pediatric cochlear implant users: I. Cochlear nerve responsiveness and electrode-neuron interface index.Hearing research · 2026
- Association of AutoART eCAP thresholds with behavioral THR and MCL in pediatric cochlear implant users.Cochlear implants international · 2026
- Establishing reliable neural health measures in adult cochlear implant users.Frontiers in neuroscience · 2026
- Is the Presence of eCAP Intraoperatively a Predictor of Cochlear Implant Outcomes in Adults?International archives of otorhinolaryngology · 2026