Onset-Triggered Vote-Locking (OTVL) for Stable Myoelectric Control of Multi-DoF Prosthetic Hands.
Alessandra Pero, Erik Gasparini, Tommaso Mori, Cristian Felipe Blanco-Diaz, Rodolfo Cerqueira, Waleed Al-Ghilan, Sophie Skach, Leonardo Cappello,
Key points
From the paper's conclusion- This study presents a novel semi-locked myoelectric pattern recognition algorithm (Onset-Triggered Vote-Locking or OTVL) to reduce misclassifications that typically occur during transition phases of muscular contractions for prosthetic hand control.
Abstract
This study presents a novel semi-locked myoelectric pattern recognition algorithm (Onset-Triggered Vote-Locking or OTVL) to reduce misclassifications that typically occur during transition phases of muscular contractions for prosthetic hand control. It segments the electromyographic signals in real-time by adaptively defining enabling and disabling conditions at the onset of a muscular contraction in order to lock classifier predictions only when they are considered stable. The segmentation is based on signal standard deviation to improve robustness and reduce the need for rest transitions between movements. The proposed algorithm was implemented with a standard Linear Discriminant Analysis (LDA). It was functionally assessed by simulating activities of daily living and compared against a continuous LDA classifier with two conventional post-processing algorithms: Majority Vote (MV) and Confidence Rejection (CR). Eleven able-bodied participants executed ten repetitions of three Southampton Hand Assessment Procedure (SHAP) tasks using a bypass socket equipped with an active wrist and a multi-articulated hand. The OTVL algorithm significantly outperformed CR in terms of success rate (median:IQR; OTVL: 100.0%:0%; CR: 10.0%:60.0%; p < 0.001). Compared to MV, OTVL significantly reduced total completion time (OTVL: 56.4s:20.6s; MV: 62.2s:7.7s; p < 0.05) and the number of incorrect preshapes (OTVL: 0.6:0.4; MV: 1.5:1.3; p < 0.01) that occurred between tasks. The perceived workload, as assessed by the NASA Task Load Index, was also significantly reduced compared to MV and CR (OTVL: 52:33.5; MV: 67:21.5; CR: 95:36.3; p < 0.001). Therefore, the OTVL algorithm represents a viable alternative to traditional continuous classifiers, improving control stability and task execution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Phase-Based Gesture Motor Learning Protocol for Training Prosthetic Control in Individuals with Transradial AmputationMethods and Protocols · 2026
- An Adaptive Multi-Representation Fusion Framework for EMG Pattern Recognition in Transradial Amputees.Bioengineering (Basel, Switzerland) · 2026
- Longevity of continuous prosthetic finger control using implanted electromyographic signals without recalibration.Research square · 2026
- A motoneuron discharge–driven interface realizing simultaneous and proportional control of prosthetics in end-usersScience Advances · 2026
- A Comprehensive Survey of Machine Learning Algorithms in Hand Gesture Recognition for Myoelectric Prosthetic Control: Current Trends, Challenges and Future DirectionsArchives of Computational Methods in Engineering · 2025
- Design and intelligent control of a low-cost, sEMG-driven, 3D-printed robotic hand prosthesis: A three-tier benchmarking framework with novel robustness metrics.Journal of electrical bioimpedance · 2026