Gas Embolism on a Chip: Mimicking Iatrogenicity at the Microscale.
K Baassiri, L Maskova, M M Mardanpour, T Allen, F Gamper, L A Flores-Asomoza, A Sudalaiyadum Perumal, D V Nicolau
Key points
From the paper's conclusion- Air embolism may occur in injured microvasculature at pressures within the lower range encountered during gastroscopy. Carbon dioxide embolism requires higher pressures, but once triggered, it can result in high-volume gas entry during laparoscopy. High pressure gas-supersaturated tissues can act as gas 'reservoirs' prolonging GE therapy.
Abstract
OBJECTIVE: Gas embolism (GE) is a potentially life-threatening condition with difficult in vivo investigation. The physical nature of the initial stages of GE makes in vitro abiotic microfluidics valuable for phenomenological studies. A versatile microfluidic system was used to mimic the microscale iatrogenic GE during gastroscopy, laparoscopy, and hyperbaric therapy under three scenarios: gas transfer through perforated or non-perforated microvasculature, and via tissue supersaturation. METHODS: Polydimethylsiloxane devices mimicking microvascular geometries, with, or without injuries, hosted the flow of artificial blood. Localized gas pressures comparable to those used in gastroscopy, laparoscopy, and hyperbaric therapy were applied on microvasculature using air, carbon dioxide or /nitrogen to mimic microscale GE. RESULTS: Air and carbon dioxide produced markedly different GE patterns. Air generated numerous small bubbles across the entire pressure range, and a distinct population of larger emboli at lower pressures. Conversely, carbon dioxide embolism occurred beyond a threshold pressure (23-58 mm Hg), but once initiated, complete blockage or continuous gas injection lasting tens of seconds occurred. CONCLUSION: Air embolism may occur in injured microvasculature at pressures within the lower range encountered during gastroscopy. Carbon dioxide embolism requires higher pressures, but once triggered, it can result in high-volume gas entry during laparoscopy. High pressure gas-supersaturated tissues can act as gas 'reservoirs' prolonging GE therapy. SIGNIFICANCE: These findings underscore the risk of air GE in gastroscopy and the need for pressure and flowrate control; possible carbon dioxide GE during laparoscopy warrants further assessment; and the duration of gas clearance during GE therapy needs to be considered.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessing the effectiveness of surfactants on the treatment of gas embolism in microfluidic networks mimicking microvasculature.Journal of colloid and interface science · 2026
- Impact of Air Bubbles on Cerebrospinal Fluid Drainage in Ventriculoperitoneal Shunts: An Experimental Validation.Neurosurgery · 2026
- Differential Air Entrainment of Mini-Basket and Circular Mapping Catheters Through the FARADRIVE Sheath: Mitigation With a Liquid-Sealed Insertion Method.Journal of cardiovascular electrophysiology · 2026
- Dynamics of entrapped air pockets under transient pressure waves in pressurized pipelines: combined numerical and experimental studyScientific Reports · 2026
- Cerebral Arterial Gas Embolism in Cardiovascular and Aortic Procedures: A Narrative Review of the Mechanisms, Diagnosis, Management, and Prevention.Journal of cardiothoracic and vascular anesthesia · 2026
- A Pressure-Controlled Optical Platform for Buckling, Gas Dissolution, and Shell Remodeling in Lipid-Coated Microbubbles.Langmuir : the ACS journal of surfaces and colloids · 2026