科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ IEEE Transactions on Applied Superconductivity2026-02-12· Magnet

Manufacturing of the EuroSIG Dipole Demonstrator Magnet for Hadrontherapy

Marco Prioli, N. Ciarchi, Gabriele Crespi, E. De Matteis, A. Palmisano, D. Pedrini, L. Rossi, A. Ruggiero, Carlo Santini, S. Sorti, R. U. Valente, E. Bianchi, S. Farinon, A. Gagno, R. Musenich, A. Pampaloni, G. Ceruti, L. Dassa, L. Gentini, D. Perini, Roland Piccin, E. Felcini, M. Pullia, O. Duran, J. A. Garcia-Matos, C. Martins Jardim, F. Toral

原始摘要(英文原文)· Original abstract
This paper reports on the updated status and manufacturing results of the EuroSIG Superconducting dipole Demonstrator Magnet (SDM-c). The SDM-c is one of the key technologies for the next-generation European heavy-ion gantry and consists of a curved cos−θ NbTi dipole with a 30° magnetic length over a 1.65 m curvature radius and a 0.15 Ts−1ramp-rate. We summarize the milestones reached in the last year, including the production of the curved dummy coil, employed to validate the manufacturing tooling and procedures, the production of the first curved NbTi coil, and the engineering and procurement of the mechanical structure, which was also complicated by the curvature. The results show that the project is in good track to prove the feasibility of the bending magnet concept. The paper includes a discussion of the remaining challenges for the final prototype magnet, which has a 45° magnetic length and a 0.4 Ts−1ramp-rate.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Manufacturing of the EuroSIG Dipole Demonstrator Magnet for Hadrontherapy — 科研速览 Science Skim