EndoCADx: A Preference-Aligned Vision-Language Framework for Standardized Descriptive Diagnosis in Upper Gastrointestinal Endoscopy.
Shan Hu, Yuhan Jiang, Tingshun Xiong, Changhong Xiao, Ruiqing Jiang, Zehua Dong, Yiyun Chen, Bin Mei,
Key points
From the paper's conclusion- We formalize a two-stage optimization pipeline comprising domain-specific supervised fine-tuning (SFT) and error-driven Direct Preference Optimization (DPO).
Abstract
The subjective nature of descriptive endoscopic diagnosis and the propensity of large vision-language models (LVLMs) to produce semantic hallucinations pose significant threats to clinical safety and standardized patient management. While computer-aided detection (CADe) systems are widely adopted for lesion localization, the transition toward standardized descriptive diagnosis (CADx) remains hindered by large model size, high inference latency, and hallucination risks. To address these barriers, we propose EndoCADx, a compact, low-latency generative framework tailored for standardized gastric descriptive diagnosis. We formalize a two-stage optimization pipeline comprising domain-specific supervised fine-tuning (SFT) and error-driven Direct Preference Optimization (DPO). By systematically mining failure-mode subsets from the initial SFT baseline, we perform targeted recalibration of the model's latent policy to improve concordance between generated descriptions and expert reference annotations. EndoCADx provides an on-demand response time of 1.46 s per physician-selected frozen keyframe, compatible with the routine "freeze-and-inspect" workflow. Extensive evaluation on EndoGastro-500, a multi-center independent cohort from six heterogeneous clinical centers, demonstrates robust performance: the DPO-aligned model achieves 91.6% Lesion Recognition Accuracy (ALR) and 84.7% Feature Description Accuracy (AFD), with the latter reflecting improved attribute-level consistency with expert annotations. A comprehensive Multi-Reader, Multi-Case (MRMC) study involving 12 endoscopists further reveals that EndoCADx acts as a standardizing agent; while conventional CADe alone yields only moderate inter-rater reliability (Kappa = 0.64), EndoCADx elevates diagnostic consistency to almost perfect agreement (Kappa = 0.88), particularly benefiting novice clinicians with a 17.20% accuracy gain. By balancing real-time efficiency with expert-aligned safety, this work offers a practical paradigm for the clinical translation of endoscopic VLMs as a reliable supplementary aid to professional judgment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EndoVLM: A Vision-Language Assistant for Gastrointestinal Endoscopy.Journal of imaging informatics in medicine · 2026
- TrustEndo: A Conformal-Calibrated MLLM With Retrieval-Augmented Reasoning for Trustworthy Gastroscopic Diagnosis.IEEE journal of biomedical and health informatics · 2026
- An explainable generative AI system for video-to-report generation in capsule endoscopy.NPJ digital medicine · 2026
- Vision-language foundation models for multimodal medical image understanding and report generation: a narrative review with quantitative synthesis.Frontiers in medicine · 2026
- EndoSCOP-V: A Multi-Turn Video Understanding Evaluation Framework for Multimodal Models in Endoscopy Reporting and Clinical ReasoningarXiv · 2026
- Evaluating Frontier Large Language Models for AI-Assisted Differential Diagnosis in Gastroenterology: A Comparative Study of Diagnostic Performance and Repeated-Run Consistency.Bioengineering (Basel, Switzerland) · 2026