Key points
From the paper's conclusion- This study analyses whether substituting those linings with 3D-printed concrete (3DPC) can enhance load bearing fire rating (LFR) and insulation fire rating (IFR) under both standard and severe hydrocarbon fire exposures.
Abstract
Purpose Conventional plasterboard linings impose a hard limit on the fire resistance of light steel frame (LSF) walls because gypsum rapidly degrades at high temperature. This study analyses whether substituting those linings with 3D-printed concrete (3DPC) can enhance load bearing fire rating (LFR) and insulation fire rating (IFR) under both standard and severe hydrocarbon fire exposures. Design/methodology/approach Eighty-eight finite-element models simulated LSF walls combining steel lipped channels and 3DPC facings. Parameters varied were 3DPC thickness (25–100 mm), cavity-insulation type (rockwool or glass fibre) and infill ratio (20–100%). Critical outputs were time to reach steel temperatures of 320 °C, 490 °C and 640 °C (load ratios 0.6, 0.4, 0.2) and time to 160/200 °C on the unexposed face. Findings Replacing 25 mm panels (IFR = 18 min in hydrocarbon fire) with 100 mm 3DPC panels extended insulation fire resistance beyond the 240-min analysis window; under the standard curve, 50 mm panels already sustained the 0.2 load ratio for over four hours. Rockwool increased IFR by up to 55% and added more than 60 min to LFR. Regression models linking thickness, fill, fire severity and insulation type achieved R2 values to 0.992. Originality/value This is the first systematic investigation of 3DPC-LSF walls under both rapid-rise hydrocarbon and standard fires. It supplies design-ready regression models and shows that 3DPC walls = 50 mm, especially with rockwool, deliver multi-hour structural and insulation fire resistance, up to 50% higher than plasterboard, making them a viable, fire-robust alternative for fire-safe LSF construction. Highlights
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Response-Specific Applicability of Equivalent Thermal Models for 3D-Printed Ribbed Wall EnvelopesBuildings · 2026
- Modulbau mit 3D‐gedruckten Betonbauteilen und subtraktiv hergestellten TrockenfugenBeton- und Stahlbetonbau · 2026
- Experimental and FEM Analysis of the Thermal Performance of Calcium Silicate Boards at High-Temperature ExposureBuildings · 2026
- Effects of Paraffin/Sisal Composite Phase Change Fibers on the Rheological and Heat-Transfer Behaviors of 3D-Printed Concrete.Materials (Basel, Switzerland) · 2026
- Fire performance of PET-based composite wall cladding reinforced with recycled steel fibers and rice husk ashDiscover Civil Engineering · 2026
- Fire Performance of Hybrid Fibre Reinforced Concrete with Steel and Sodium Carbonate-Treated Natural Fibres Under Standard Fire ExposureConstruction Materials · 2026