Spectroscopy of ^{4}He at 0.25 ppt Uncertainty and Improved Alpha-Helion Charge-Radius Difference Determination.
K Steinebach, J C J Koelemeij, H L Bethlem, K S E Eikema
Vrije Universiteit Amsterdam, Department of Physics and Astronomy, LaserLaB, De Boelelaan 1100, 1081 HZ Amsterdam, The Netherlands.
Key points
From the paper's conclusion- Combined with previous ^{3}He measurements and improved theory, we obtain the most precise determination to date of the charge-radius difference between the helion and alpha particle (r_{h}^{2}-r_{α}^{2}) of 1.0676(10) fm^{2}.
Abstract
High-precision spectroscopy of simple atomic systems can be used to advance the theory of atomic energy levels but can also serve as a sensitive probe of nuclear charge radii. For this last purpose, we report an improved measurement of the 2^{3}S_{1}→2^{1}S_{0} transition frequency in ^{4}He with 48 Hz uncertainty (0.25 ppt), using a Bose-Einstein condensed sample confined in a magic-wavelength optical dipole trap. A systematic Doppler shift from condensate motion is suppressed by time-resolved ion detection, and the transition frequency is calibrated via a White Rabbit link to a remote active hydrogen maser clock. Combined with previous ^{3}He measurements and improved theory, we obtain the most precise determination to date of the charge-radius difference between the helion and alpha particle (r_{h}^{2}-r_{α}^{2}) of 1.0676(10) fm^{2}. This is consistent with other recent determinations and confirms that the current discrepancy between QED theory and experimentally observed ionization energies of excited states in helium is not apparent in the isotope shift.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improved systematic evaluation of a strontium optical clock with uncertainty below 1 × 10 − 18Metrologia · 2026
- Precision Isotope-Shift Measurement of the ^{1}S_{0}↔^{3}P_{2} Transition and a Multitransition King-Plot Consistency Test.Physical review letters · 2026
- Liquid-Nitrogen-Cooled ^{40}Ca^{+} Ion Optical Clock with a Systematic Uncertainty of 4.4×10^{-19}.Physical review letters · 2026
- Lu+ optical frequency references with accuracy verified at the 19th digit.Nature · 2026
- Transportable strontium lattice clock with 4 × 10 − 19 blackbody radiation shift uncertaintyQuantum Science and Technology · 2025
- Beam geometry and temperature effects on the frequency stability of a⁸⁷ Rb two-photon optical frequency standardJournal of Physics B Atomic Molecular and Optical Physics · 2026