Weak-charge form-factor determination at the electron-ion collider
Hooman Davoudiasl, Hongkai Liu, Sonny Mantry, Ethan T. Neil
Brookhaven National Laboratory · University of North Georgia
Key points
From the paper's conclusion- We show that with data corresponding to an integrated luminosity of <s:math xmlns:s="http://www.w3.org/1998/Math/MathML" display="inline"> <s:mi mathvariant="script">L</s:mi> <s:mo>∼</s:mo> <s:mn>500</s:mn> <s:mo>/</s:mo> <s:mi>A</s:mi> <s:mtext> </s:mtext> <s:mtext> </s:mtext> <s:mrow> <s:msup> <s:mrow> <s:mi>fb</s:mi> </s:mrow> <s:mrow> <s:mo>−</s:mo> <s:mn>1</s:mn> </s:mrow> </s:msup> </s:mrow>
Abstract
Determining the weak charge form factor, F W ( Q 2 ) , of nuclei over a continuous range of momentum transfers, 0 ≲ Q 2 ≲ 0.1 GeV 2 , is essential for mapping out the distribution of neutrons in nuclei. The neutron density distribution has significant implications for a broad range of areas, including studies of nuclear structure, neutron stars, and physics beyond the Standard Model. Currently, our knowledge of F W ( Q 2 ) comes primarily from fixed target experiments that measure the parity-violating asymmetry in coherent elastic electron-ion scattering. Fixed target experiments, such as CREX and PREX-1,2, have provided high-precision weak charge form factor extractions for the Ca 48 and Pb 208 nuclei, respectively. However, a major limitation of fixed target experiments is that they each provide data only at a single value of Q 2 . With the proposed electron-ion collider (EIC) on the horizon, we explore its potential to impact the determination of the weak charge form factor. While it cannot compete with the precision of fixed target experiments, it can provide data over a wide and continuous range of Q 2 values, and for a wide variety of nuclei. We show that with data corresponding to an integrated luminosity of L ∼ 500 / A fb − 1 , where A is the nucleus atomic weight, the EIC can significantly impact constraints by lifting degeneracies in theoretical models of the neutron density distribution. Ensuring EIC detector coverage at low Q 2 and large negative pseudorapidities will be essential for such F W ( Q 2 ) measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electroweak Constraints on Nuclear Neutron Distributions and the Low-Energy Weak Mixing AnglearXiv · 2026
- First observation of weak magnetism in neutron decayarXiv · 2026
- Weak charged current induced electron and positron scattering off proton at JLab and MAMI energiesJournal of Physics G: Nuclear and Particle Physics · 2026
- Isospin violation and the neutron weak magnetic momentarXiv · 2026
- Nuclear Charge Radii from Precision Bound-Electron g-Factor MeasurementsarXiv · 2026
- Characterizing the nuclear models informed by PREX and CREX: A view from Bayesian inferencePhysical Review Research · 2025