Detection of eukaryotic micro-organisms in human clinical samples by shotgun metagenomics: read-based thresholds and determinants of performance.
Théo Ghelfenstein-Ferreira, Cécile Angebault, Vanessa Demontant, Laure Boizeau, Sandrine Houze, Christophe Rodriguez, Françoise Botterel
Département de Prévention Diagnostic et Traitement des Infections, Unité de Parasitologie-Mycologie, AP-HP, Hôpital Henri-Mondor, F-94010 Créteil, France. · Département de Prévention Diagnostic et Traitement des Infections, Genobiomics platform, AP-HP, Hôpital Henri-Mondor, F-94010 Créteil, France.
Key points
From the paper's conclusion- These results establish a quantitative, RPM-based framework for eukaryotic micro-organism detection in clinical metagenomics and a foundation for future multi-platform benchmarking studies.
Abstract
Bioinformatic detection thresholds for eukaryotic micro-organisms (fungi and parasites) remain largely undefined in human clinical shotgun metagenomics (SMg), limiting standardized implementation. We retrospectively compared SMg with standard of care (SoC) across 198 clinical samples from 187 patients to derive reads per million (RPM)-based detection thresholds for fungi and parasites across 5 major sample types. Total nucleic acids were sequenced (≥10 million reads per library) and processed with the MetaMIC® v2.2.1 pipeline. Read counts were normalized as RPM. SoC identified micro-organisms in 152/198 samples (76.8%), spanning 44 eukaryote genera and 57 species; all 46 SoC-negative samples were also negative by SMg. The overall genus-level F1-score was 0.84, with performance varying by sample type: blood and biological fluids achieved the highest concordance (F1=0.98 and 0.97, respectively). Microbial load was the principal determinant of SMg sensitivity, with quantification cycle (Cq) values (n=57) inversely correlating with RPM (Spearman's ρ=-0.66, P<0.001) and no false negatives at Cq<28.6. Receiver operating characteristic-derived optimal thresholds ranged from 0.06 RPM (faeces, Area Under the Curve [AUC] 0.91) to 0.57 RPM (tissue biopsies, AUC 0.90). A global threshold of 0.06 RPM yielded an AUC of 0.93 (95% confidence interval: 0.90-0.95; sensitivity 87.8%, specificity 90.7%). These results establish a quantitative, RPM-based framework for eukaryotic micro-organism detection in clinical metagenomics and a foundation for future multi-platform benchmarking studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A framework of Microbial Genomic Database for clinical metagenomic pathogen diagnosis: development and multi-cohort evaluation.Frontiers in cellular and infection microbiology · 2026
- A Framework for Analytical Validation of Genomic DNA-Based Shotgun Metagenomic Next-Generation Sequencing WorkflowsmedRxiv · 2026
- Repurposing Shotgun Metagenomic Human Host Reads for Mitochondrial Heteroplasmy DetectionmedRxiv · 2026
- Metagenomic next-generation sequencing enhances diagnosis of fungal infections in kidney transplant recipients: a retrospective studyFrontiers in Cellular and Infection Microbiology · 2026
- Random PCR-based nanopore whole-genome sequencing enables pre-positivity detection of fungal bloodstream infections.Microbiology spectrum · 2026
- Unveiling pathogens and contaminants: refining metagenomics for clinical diagnosticsFrontiers in Microbiology · 2026