Journal of the American College of Surgeons

Evaluation of Vision-Language Models for Surgical Narration and Critical View of Safety Assessment in Laparoscopic Cholecystectomy.

Rita Glazer, Philip Seger, Brendan Fox, Garrett Skinner, Jiajie Li, Kaity Tung, Andrew Chang, Jeremy Walsh,

From the Department of Surgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, NY.

Key points

From the paper's conclusion
  • Procedure-specific prompting increased similarity to attending narration without consistently improving procedural content. Divergent CVoS errors demonstrate that fluent surgical narration does not establish reliable safety assessment. VLM narration may support surgeon-reviewed documentation, but safety-critical judgments require separate task-specific validation.

Abstract

BACKGROUND: Vision-language models (VLMs) may support surgical documentation through operative video narration, but fluent narration may not capture procedural details or safety-critical anatomy. We compared VLM-generated laparoscopic cholecystectomy narrations with surgeon narration and evaluated Critical View of Safety (CVoS) assessment. STUDY DESIGN: Forty-eight 10-minute segments from 13 Cholec80 videos were evaluated using Gemini 2.5 Flash (Untrained VLM) and Qwen3-VL-CoA (Surgically Trained VLM) under Basic and procedure-specific prompting. VLM and surgeon narrations were compared for structure, semantic similarity, checklist-based procedural content, and CVoS recognition. RESULTS: Attending narrations averaged 490.6 words versus 243.9-252.5 for VLMs. Specific prompting increased cosine similarity for both VLMs (0.507 to 0.593 and 0.543 to 0.584; both adjusted p<0.001), but checklist F1 improved only for the Untrained VLM (0.405 to 0.501; adjusted p=0.006), not the Surgically Trained VLM (0.337 to 0.380; adjusted p=0.233). Among 6 CVoS-positive and 42 CVoS-negative segments, Untrained Specific had sensitivity 0.33 (95% CI 0.10-0.70) and specificity 0.95 (95% CI 0.84-0.99); Surgically Trained Specific had sensitivity 0.83 (95% CI 0.44-0.97) and specificity 0.19 (95% CI 0.10-0.33). CONCLUSIONS: Procedure-specific prompting increased similarity to attending narration without consistently improving procedural content. Divergent CVoS errors demonstrate that fluent surgical narration does not establish reliable safety assessment. VLM narration may support surgeon-reviewed documentation, but safety-critical judgments require separate task-specific validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers