A Comparative Randomized Crossover Pilot Study Comparing Male External Urine Collection Devices in Home Settings.
Adrian Wagg
Adrian Wagg, MBBS FRCP (Lond) FRCP (Edin) FCGS FHEA, Division of Geriatric Medicine, Department of Medicine, University of Alberta, Edmonton, Alberta, Canada.
Key points
From the paper's conclusion- In older men requiring nocturnal urine management at home, the male external urine collection device demonstrated capture performance and safety comparable to a sheath-style catheter, with strong participant preference for the external collection device.
Abstract
PURPOSE: The purpose of this study was to compare nighttime urine capture, safety, and participant preference between a male external catheter connected to a vacuum-assisted collection system and a male condom catheter in community-dwelling older men who previously used incontinence products at night. DESIGN: Prospective, open label, randomized, 2-phase crossover pilot study. PARTICIPANTS AND SETTING: Fifteen older men (≥65 years) requiring nocturnal urine management were enrolled across 2 US outpatient research sites (Greenacres, FL; Hamilton, NJ). Data were collected March-June 2025 in participants' home setting. METHODS: Participants were randomized 1:1 to device sequence and used each device for 7 consecutive nights separated by a ≥2-day washout. Primary outcomes assessed mean nightly urine capture rate (performance) and device-related adverse events requiring medical intervention (safety). Secondary endpoints included device preference, dislodgement, and tolerability, whereas changes in the PROMIS Sleep Disturbance scale before and after the use of each device were captured as exploratory endpoints. Analyses were descriptive with paired comparisons and beta regression for capture rate. RESULTS: Fifteen participants completed both 7 night usage periods. Mean (SD) overall capture rate was 98.5% (1.7) with the study device (MEC) versus 98.1% (2.6) with the comparator (sheath; LS mean difference 0.5%, 95% CI -0.8 to 1.7). No device-related adverse events requiring medical intervention were reported. Device dislodgement occurred infrequently for both devices and was numerically higher for the male external catheter, with events primarily occurring during the first treatment phase and driven by repeated dislodgements in a single participant. Preference favored the study device (13/15, 86.7%). The PROMIS Sleep Disturbance scale decreased (improved) from baseline in both periods (mean change -8.6 and -6.3). CONCLUSIONS: In older men requiring nocturnal urine management at home, the male external urine collection device demonstrated capture performance and safety comparable to a sheath-style catheter, with strong participant preference for the external collection device.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An economic evaluation of the MultICath randomised controlled trial, comparing combined use of reusable and single-use intermittent catheters to single-use catheters onlyCost Effectiveness and Resource Allocation · 2026
- PaceyCuff for male stress urinary incontinence: first UK pilot evaluation of clinical outcomes and short-term cost offset.Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy · 2026
- Self-reported verbal assessment in the evaluation of urinary continence after 3D-laparoscopic prostatectomy: a single-centre prospective registered study.Scandinavian journal of urology · 2026
- 'Efficacy and safety outcomes after slings or artificial urinary sphincter implantation for non-neurogenic male stress urinary incontinence: a systematic review' for more clarity.Frontiers in urology · 2026
- Patient acceptance of clean intermittent self-catheterization: Comparing urethral route and Mitrofanoff stoma.JPMA. The Journal of the Pakistan Medical Association · 2026
- Ultrasound-assisted dynamic bladder function for predicting successful catheter removal in male ICU patients: a prospective cohort study.BMC anesthesiology · 2026