How Reliable and Reproducible Is Optical Coherence Tomography in Idiopathic Intracranial Hypertension? When Agreement Deteriorates in Advanced Papilledema.
Vineet S Kumar, Chiamaka J P Okeke, Grant C Goodfellow, John T Reaves, Luke W Barrick, Laiba A Khalil, David I Kaufman
Department of Neurology and Ophthalmology (VSK, CJPO, JTR, LWB, LAK, DIK), Michigan State University, East Lansing, Michigan; and Department of Ophthalmology (GCG), Henry Ford Warren, Warren, Michigan.
Key points
From the paper's conclusion- In this exploratory study, automated OCT segmentation demonstrated substantial divergence from manually corrected pRNFL measurements in higher-grade papilledema, with discrepancies exceeding 150 µm in advanced disease. The reliability of manual correction decreased to moderate levels with increasing Frisén grade. These findings underscore the need to interpret OCT-derived pRNFL measurements cautiously and in conjunction with the clinical examination in higher-grade papilledema.
Abstract
BACKGROUND: Optical coherence tomography (OCT)-derived peripapillary retinal nerve fiber layer (pRNFL) thickness is central to monitoring papilledema in idiopathic intracranial hypertension (IIH). However, the structural distortion caused by optic disc edema impairs automated segmentation accuracy, particularly in advanced disease. The magnitude of discrepancy between automated and manually corrected pRNFL measurements across Frisén grades has not been fully characterized. METHODS: In this retrospective observational study conducted at a tertiary neuro-ophthalmology clinic, 62 eyes were analyzed, including 32 eyes from 16 patients with IIH and 30 non-IIH control eyes from 15 control participants. Papilledema severity was graded by a masked neuro-ophthalmologist using the Frisén scale (Grades 1-5). pRNFL thickness was measured using the Heidelberg SPECTRALIS spectral domain OCT system. Automated segmentation outputs were independently reviewed and manually corrected by 2 masked graders: a clinical neuro-ophthalmology fellow and an ophthalmology resident, both with neuro-ophthalmology experience. Agreement between automated and manually corrected measurements was assessed using linear mixed-effects models. Intergrader reliability was evaluated with intraclass correlation coefficients (ICCs), stratified by the Frisén grade. RESULTS: No statistically significant differences between automated and manually corrected pRNFL measurements were observed at Frisén Grade 1 (mean difference -1.1 µm, P > 0.05) or Grade 2 (-15.6 µm, P > 0.05). A trend toward significance emerged at Grade 3 (29.9 µm, P < 0.1), with large, statistically significant divergence at Grades 4 (182.4 µm, P < 0.001) and 5 (158.7 µm, P < 0.001). Sector-specific analysis revealed greater discrepancy in the temporal superior, temporal inferior, and nasal inferior sectors at Grade 3, with increasing nasal superior involvement at Grades 4-5. Intergrader ICC was good in control eyes (0.892) and lower-grade papilledema (Grades 1-2: ICC = 0.807) but decreased to moderate at higher grades (Grades 3-5: ICC = 0.449). CONCLUSIONS: In this exploratory study, automated OCT segmentation demonstrated substantial divergence from manually corrected pRNFL measurements in higher-grade papilledema, with discrepancies exceeding 150 µm in advanced disease. The reliability of manual correction decreased to moderate levels with increasing Frisén grade. These findings underscore the need to interpret OCT-derived pRNFL measurements cautiously and in conjunction with the clinical examination in higher-grade papilledema.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optical coherence tomography imaging device comparison study in papilloedema secondary to idiopathic intracranial hypertension.Eye (London, England) · 2026
- Diagnostic performance of conventional optical coherence tomography parameters for differentiating pediatric papilledema from pseudopapilledema.BMC ophthalmology · 2026
- OCT RNFL Sector-Specific Analysis for Papilledema Detection: PHOMS or Drusen Coexistence in 41% of Cases Does Not Reverse Diagnostic Discrimination.Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society · 2026
- Evaluation of CSF pressures, OCT parameters, and transorbital ultrasonographic measurements in ıdiopathic ıntracranial hypertension.International ophthalmology · 2026
- Correlation of Pre-Operative Retinal Nerve Fiber Layer Thickness with Visual Recovery Following Decompression of Pituitary MacroadenomaInternational Journal of Drug Delivery Technology · 2026
- Visual field asymmetry indices and optical coherence tomography in the differential diagnosis of glaucomatous and pituitary adenoma-related optic neuropathies.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026