Influence of the Choice of the Measurement Plane on Infant Head Shape Indices: An Examination Using a Statistical Shape Model.
Mitsutoshi Yamada
Babycure Massage Therapy Practice, Toshima-ku, Tokyo, Japan.
Key points
From the paper's conclusion- The height of the measurement plane systematically alters infant head shape indices; the effect scales with deformation, and a top-view silhouette approximates the conventional 3-dimensional plane.
Abstract
The cranial vault asymmetry index (CVAI) and the cephalic index (CI) quantify infant head shape, but the convention for setting the height of the measurement plane varies across facilities. From a public statistical shape model of the infant head, 2000 synthetic shapes were generated, 500 in each of 4 classes. Taking the plane through the bilateral tragi and the sellion as reference, CVAI and CI were obtained at level 3, the third of 10 equal divisions to the vertex, at the eyebrow-height horizontal plane and from the top-view silhouette, and compared within each individual. Relative to level 3, the eyebrow-height plane gave a CI larger by 6.14 and a CVAI smaller by 0.75 in all 4 classes. Every individual showed the larger CI; 71% showed the smaller CVAI, with limits of agreement crossing 0. In sensitivity analyses, the sign of the CI difference remained consistent, whereas that of the CVAI reversed when the plane was raised to 20 mm above the canthus. The CVAI difference increased with deformation, behaving as compression (slope 0.833), not a fixed offset; regression removed the systematic deviation in a confirmation sample but narrowed the limits of agreement only from 5.72 to 4.77 points. The top-view silhouette lay close to level 3 rather than the eyebrow-height plane, with its CVAI differing by <0.5 and its CI by 1.59 at 40 cm. The measurement convention, including the plane, should be stated and unified; without a 3-dimensional device, a top-view photograph is the closest substitute. The height of the measurement plane systematically alters infant head shape indices; the effect scales with deformation, and a top-view silhouette approximates the conventional 3-dimensional plane.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Where the Inaccuracy in Cranial Shape Measurement Comes From: Measurement Convention, Point Placement, and a 20-Point Alternative.The Journal of craniofacial surgery · 2026
- Charting neuroimaging-based head circumference and cranial shape across development.bioRxiv : the preprint server for biology · 2026
- Three-Dimensional Surface Topography for Entropy-Based Comparison of Sagittal Postural Classifications in Children.Sensors (Basel, Switzerland) · 2026
- Association of cephalic index with corpus callosum and cavum septi pellucidi measurements during second-trimester neurosonography.Journal of perinatal medicine · 2026
- Computed Tomography-Based Evaluation of Positional Cranial Deformities in Emergency Department Patients Aged 15 to 39 Years in Japan.The Journal of craniofacial surgery · 2026
- Inside from outside: head-to-skull-and-muscles translation with statistical shape relation and multiple region-of-interest learning.Medical & biological engineering & computing · 2026