In Vivo Ankle Tendon Quantification Using Ultrashort Echo Time Magnetization Transfer Imaging.
Georg C Feuerriegel, Damian Mialkowskyj, Adrian A Marth, Stefan Sommer, Reto Sutter
Department of Radiology, Balgrist University Hospital, Faculty of Medicine, University of Zurich, Zurich, Switzerland (G.C.F., A.A.M., R.S.); Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA (G.C.F.); Department of Diagnostic and Interventional Neuroradiology, University Hospital of Munich, Ludwig-Maximilians University, Munich, Germany (D.M.); Swiss Center for Musculoskeletal Imaging (SCMI), Balgrist Campus, Zurich, Switzerland (S.S., R.S.); Swiss Innovation Hub, Siemens Healthineers International AG, Zurich, Switzerland (S.S.).
Key points
From the paper's conclusion- In vivo ankle tendon quantification using UTE MT is feasible within clinically acceptable acquisition times and shows significantly lower intersubject variability than UTE T2* mapping in most tendons, with reduced susceptibility to the magic angle effect. UTE MT represents a promising approach for quantitative assessment of tendon structure in vivo.
Abstract
OBJECTIVES: To quantitatively assess in vivo ankle tendons using less magic angle-sensitive 3-dimensional ultrashort echo time magnetization transfer (UTE MT) imaging and to compare its intersubject variability with UTE T2* mapping in healthy volunteers. MATERIALS AND METHODS: Thirty healthy volunteer ankles were examined on a 3T MRI system using a standardized clinical protocol with additional 3D UTE MT and 3D multi-echo UTE T2* sequences (acquisition times: 4:16 and 9:52 minutes, respectively). Nine major ankle tendons were semi-automatically segmented to extract quantitative UTE MTR and UTE T2* values for each tendon. Variability for each sequence was assessed using the coefficient of variation (CV), and differences in CV were evaluated primarily with a paired bootstrap of the CV ratio and secondarily with a modified signed log-likelihood ratio (MSLR) test, both with Holm correction. Within-tendon angular dependence was assessed using local tendon fiber angles relative to B0. RESULTS: Absolute quantitative values differed between tendons, with the Achilles tendon demonstrating the lowest T2* values (2.15±0.43 ms) and highest MTR values (0.44±0.08), whereas smaller positional tendons showed higher T2* and lower MTR values. UTE MTR demonstrated lower overall variability compared with UTE T2* values across the 9 assessed tendons (overall CV UTE MTR: 18.0%±4.2% vs. UTE T2*: 33.7%±8.9%, mean±SD, n=9). In the paired bootstrap analysis with Holm correction, UTE MTR showed significantly lower variability than UTE T2* in 6 of 9 tendons, with the largest differences in the extensor digitorum longus, peroneus brevis, and flexor hallucis longus tendons (T2*/MTR CV ratio, 2.74, 2.60, and 2.48; all Holm-adjusted P≤0.015); MSLR results were consistent. Between 0 degree and the magic angle, UTE T2* increased by 79% (95% CI: 64%-95%), whereas UTE MTR decreased by 9% (95% CI: 7%-11%). UTE MTR consistently demonstrated reduced dispersion and narrower value distributions compared with UTE T2*. CONCLUSIONS: In vivo ankle tendon quantification using UTE MT is feasible within clinically acceptable acquisition times and shows significantly lower intersubject variability than UTE T2* mapping in most tendons, with reduced susceptibility to the magic angle effect. UTE MT represents a promising approach for quantitative assessment of tendon structure in vivo.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrashort Echo Time Magnetization Transfer MR Imaging of Lumbar Nerve Roots in Patients With Disc HerniationJournal of Magnetic Resonance Imaging · 2026
- In-vivo identification of subject-specific Achilles subtendon twistJournal of Biomechanics · 2026
- Clinical applications of UTE-T2* in knee MRISkeletal Radiology · 2026
- A reproducible method to image the rat Achilles tendon anatomy by 7 Tesla Magnetic Resonance Imaging (MRI) - a feasibility technical note.Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft · 2026
- Quantitative UTE MRI Differences in the Meniscus Following ACL Reconstruction: A Prospective Cohort Study Using 3D Ultrashort Echo Time Adiabatic T1rho and Magnetization Transfer Imaging.Journal of magnetic resonance imaging : JMRI · 2026
- Feasibility of a 2-Minute Multi-Echo UTE Acquisition for Simultaneous CT-Like Bone-Weighted Imaging and Quantitative T2* Mapping of Short-T2 TissuemedRxiv · 2026