Journal of computer assisted tomography

MRI Features of Endometrial Hyperplasia With and Without Atypia and Early-Stage Endometrioid Carcinoma.

Yukako Iritani, Hiroki Kato, Tomohiro Kanayama, Kyoko Kikuno, Tatsuro Furui, Masanori Isobe, Masaya Kawaguchi, Yoshifumi Noda,

Departments of Radiology. · Tumor Pathology.

Observational · n=304

Key points

From the paper's conclusion
  • Several MRI features, particularly ADC values, T2-weighted signal characteristics, small intralesional cysts, and intraluminal linear structures, may aid differentiation of EH from stage IA EEC. Discrimination between EHWA and EAH was modest and requires validation.

Abstract

OBJECTIVE: This study aimed to evaluate magnetic resonance imaging (MRI) features of endometrial hyperplasia (EH) and stage IA endometrial endometrioid carcinoma (EEC), and to assess MRI findings for distinguishing EH from EEC and for differentiating endometrial hyperplasia without atypia (EHWA) from endometrial atypical hyperplasia (EAH). METHODS: A total of 304 patients were retrospectively reviewed, including 107 with histopathologically confirmed EH (45 EHWAs and 62 EAHs) and 197 with stage IA EEC, all of whom underwent MRI with diffusion-weighted imaging within 3 months before hysterectomy or biopsy/dilation and curettage. MRI findings were compared across groups. RESULTS: The frequencies of small intralesional cysts on T2-weighted (21% vs. 5%) and fat-suppressed contrast-enhanced T1-weighted (19% vs. 4%) images and intraluminal linear structures on T2-weighted (12% vs. 2%) and fat-suppressed contrast-enhanced T1-weighted (23% vs. 5%) images were higher in EH than in stage IA EEC, respectively (P<0.01). Signal intensity ratios on T2-weighted (2.45±1.14 vs. 1.66±0.65) and fat-suppressed contrast-enhanced T1-weighted (0.97±0.27 vs. 0.81±0.22) images, and apparent diffusion coefficient (ADC) values (1.29±0.34 vs. 0.84±0.18×10-3 mm2/s) were higher in EH than in stage IA EEC, respectively (P<0.01). When comparing EHWA and EAH, the frequencies of small intralesional cysts on T2-weighted images (31% vs. 13%) and ADC values (1.38±0.34 vs. 1.22±0.33×10-3 mm2/s) were higher in EHWA than in EAH, respectively (P<0.05). CONCLUSIONS: Several MRI features, particularly ADC values, T2-weighted signal characteristics, small intralesional cysts, and intraluminal linear structures, may aid differentiation of EH from stage IA EEC. Discrimination between EHWA and EAH was modest and requires validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers