Volar rim fracture of the distal radius: management when fragment-specific fixation is not feasible - a case report.
Hesam Alitaleshi, Kamran Eftekhari, Seyed A Seyedifard
Center for Orthopedic Trans-Disciplinary Applied Research, Tehran University of Medical Sciences, Tehran, Iran. · Department of Orthopedics, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran.
Key points
From the paper's conclusion- The pin-and-plate technique represents an effective surgical option for managing selected volar rim fractures of the distal radius when fragment-specific fixation is not feasible, providing satisfactory clinical and radiological outcomes while maintaining radiocarpal stability.
Abstract
INTRODUCTION AND IMPORTANCE: Volar rim fractures of the distal radius are uncommon injuries, accounting for approximately 1-11% of distal radius fractures. Despite their rarity, they are clinically significant because of their association with critical radiocarpal ligament attachments and the technical challenges of achieving stable fixation, particularly when the volar fragment is too small for fragment-specific implants. CASE PRESENTATION: A 24-year-old female sustained a volar rim fracture of the distal radius with radiocarpal subluxation following a motor vehicle accident. Surgical fixation was performed through an extended flexor carpi radialis approach. Fracture reduction was achieved using Kirschner wires and stabilized with a 3.5-mm buttress plate because fragment-specific fixation was not feasible. At the 6-month follow-up, the patient had regained full wrist range of motion, was pain-free, and had returned to normal daily activities without evidence of radiographic instability. CLINICAL DISCUSSION: Stable fixation of volar rim fractures remains technically demanding because standard volar locking plates may inadequately capture small distal fragments and have been associated with failure rates of up to 24%. Although fragment-specific fixation remains the preferred treatment when feasible, the pin-and-plate technique provides a practical and reliable alternative in situations where dedicated implants are unavailable or cannot be applied safely. CONCLUSION: The pin-and-plate technique represents an effective surgical option for managing selected volar rim fractures of the distal radius when fragment-specific fixation is not feasible, providing satisfactory clinical and radiological outcomes while maintaining radiocarpal stability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Volar Rim Morphology and Plate Congruence in Fragment-Specific Distal Radius Fixation.Hand surgery & rehabilitation · 2026
- Does additional radial column plating improve clinical and radiological outcomes in distal radius fractures with radial styloid involvement or severe comminution?: A retrospective cohort study with 2-year follow-up.Medicine · 2026
- Proximal Row Carpectomy for Established Post-Traumatic Radiocarpal Arthritis Following Distal Radius Volar Rim and Scaphoid Fractures: A Case Report.Journal of orthopaedic case reports · 2026
- Dorsal subchondral arc line: A novel radiographic marker to avoid dorsal screw prominence during distal radius fixation with volar locking plates.Injury · 2026
- Improved Ulnar Plate Positioning Using the WHAM (Wrist Henry Approach Modification) for Volar Rim Fixation of Distal Radius Fractures.Hand surgery & rehabilitation · 2026
- Distractor-assisted Reduction for Volar Shear Distal Radius Fractures: A Retrospective Case Series.Orthopedics · 2026