Cyanoacrylate-Based Skin Adhesives and Incisional Complications in Panniculectomy and Abdominoplasty: A Retrospective Cohort Study.
Steven Zeng, Thomas Ren, Fares Lebbos, Ricardo Rodriguez-Colon, Charbel Saad, Damon Cooney, Gedge Rosson
Department of Plastic and Reconstructive Surgery, Johns Hopkins University School of Medicine, Baltimore, MD.
Key points
From the paper's conclusion- CYA adhesives were associated with a higher overall incisional complication rate than SFM. Findings for individual complications were not robust and are reported as exploratory. These data support prospective evaluation of dressing selection.
Abstract
BACKGROUND: Comparative data on dressing selection after abdominal contouring, where closures bear high tension, remain limited. This study evaluated the association between dressing type and postoperative complications following abdominoplasty and panniculectomy. METHODS: Single-institution retrospective cohort study of patients undergoing abdominoplasty or panniculectomy. Dressings were silk fibroin mesh (SFM), Steri-Strips (STE), Aquacel (AQU), and cyanoacrylate adhesives (CYA); the CYA arm comprised Histoacryl (n=43), Dermabond (n=11), and Dermabond Prineo (n=10), analyzed both pooled and separately. Sensitivity analyses excluded fleur-de-lis incisions, restricted CYA to liquid formulations, and restricted to surgeons using both dressings. RESULTS: Of 125 patients, 64 received CYA, 39 SFM, 14 AQU, and 8 STE. Mean age was 47.4 years; mean BMI 33.4 kg/m2. Groups differed at baseline in ASA class, mesh use, and incision pattern, and in resection weight among the 72 patients with recorded values; fleur-de-lis incisions occurred only in CYA (n=7) and STE (n=2). Total complications were lower with SFM than CYA (15.4% vs 50.0%, p<0.001; aOR 0.17, 95% CI 0.06-0.45), an association that persisted across every sensitivity analysis, including fleur-de-lis exclusion (aOR 0.22, 95% CI 0.07-0.60, p=0.004) and separate analysis of each CYA product. Wound dehiscence and skin reaction were also lower with SFM, but these associations were not robust: with fleur-de-lis cases excluded, dehiscence (p=0.114) and skin reaction (p=0.137) were nonsignificant. CONCLUSIONS: CYA adhesives were associated with a higher overall incisional complication rate than SFM. Findings for individual complications were not robust and are reported as exploratory. These data support prospective evaluation of dressing selection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A comparative study of conventional suturing versus tissue adhesives in plastic surgery wound closureBioinformation · 2026
- Allergic Contact Dermatitis to 2-Octyl Cyanoacrylate After Total Joint Arthroplasty: A Single-Surgeon Case Series.Arthroplasty today · 2026
- A prospective randomised controlled trial comparing tissue adhesive and sutures for laparoscopic port-site skin closure.Journal of minimal access surgery · 2026
- Cyanoacrylate tissue adhesives versus sutures for planned extraoral skin closure in oral and maxillofacial surgery: a systematic reviewMaxillofacial Plastic and Reconstructive Surgery · 2026
- Multicentric pragmatic randomized controlled trial of mesh fixation system in primary and recurrent ventral hernia repair.Updates in surgery · 2026
- Allergic contact dermatitis following usage of adhesive mesh dressing in knee replacement surgeries does not affect short term outcome.Journal of orthopaedic surgery (Hong Kong) · 2026