Human Factors-Driven Optimization of Pediatric Resuscitation Workflow Using Integrated Color-Coded Systems: A Randomized Crossover Study.
Manal A Halwani, Abdullah A Bakhsh
Department of Emergency Medicine, Faculty of Medicine, King Abdulaziz University, Jeddah, Saudi Arabia.
Key points
From the paper's conclusion- In this randomized crossover simulation study, the integrated color-coded system reduced equipment retrieval and medication preparation times for selected pediatric resuscitation tasks. These findings are limited to the simulation setting and should be interpreted in light of the Broselow framework's use for both cart organization and assessment of correct equipment selection. Further research is needed to evaluate the feasibility of color-coded prefilled syringes and determine whether the observed workflow benefits translate to real-world pediatric patient care.
Abstract
AIM: This study evaluated whether a human factors-driven, integrated, color-coded resuscitation system that combines equipment standardization and prefilled-medication cognitive aids improves workflow efficiency and accuracy compared with a conventional crash cart during simulated pediatric resuscitations. METHODS: A prospective, randomized, crossover simulation study was conducted with 28 health care professionals. Each team participated in 2 pediatric resuscitation scenarios using either the SCC or the CCCC in random order. All sessions were video-recorded to measure equipment retrieval and medication preparation times. Statistical comparisons were made using paired statistical tests appropriate for crossover designs, with significance set at P<0.05. RESULTS: Use of the CCCC significantly reduced the time to locate airway devices (13.1±6.9 vs. 41.7±22 s, P<0.001) and airway adjuncts (13.8±11.9 vs. 30.8±17.4 s, P=0.03). Prefilled color-coded syringes significantly reduced medication preparation time (median: 16 vs. 19 s; absolute reduction 3 s, P=0.04), with no dosing errors observed. Teams using the CCCC demonstrated more consistent workflow and fewer procedural delays. CONCLUSIONS: In this randomized crossover simulation study, the integrated color-coded system reduced equipment retrieval and medication preparation times for selected pediatric resuscitation tasks. These findings are limited to the simulation setting and should be interpreted in light of the Broselow framework's use for both cart organization and assessment of correct equipment selection. Further research is needed to evaluate the feasibility of color-coded prefilled syringes and determine whether the observed workflow benefits translate to real-world pediatric patient care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Overview of a User-Centered, Mixed-Methods Process for Designing Interconnected and Focused Mobile Applications on Patient Care Environment (InterFACE): Augmented-Reality Decision Support System for Pediatric ResuscitationJMIR Human Factors · 2025
- A practical study on a stepwise simulation intervention guided by video review to improve the quality of cardiopulmonary resuscitation in the pediatric emergency department.Frontiers in pediatrics · 2026
- 89 Reducing cognitive load and medication preparation time in paediatric emergencies with NurEx medication dosing platformPaediatrics & Child Health · 2026
- A standardized ECPR activation protocol and resuscitation efficiency, patient outcomes, and nursing cognitive load: a retrospective multicenter study.Frontiers in cardiovascular medicine · 2026
- Immediate learning outcomes of AI- and sensor-integrated versus face-to-face CPR retraining for chest compression quality: A randomized trialDigital Health · 2026
- Dual-Channel Sensing and Event-Based Feedback for Cardiopulmonary Resuscitation Training.Sensors (Basel, Switzerland) · 2026