Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies

Flow-to-Compliance Ratio as a Bedside Marker of Strain Rate in Pediatric Acute Respiratory Distress Syndrome: Analysis of Observational Cohort Data From 2022.

Pablo Cruces, Marjorie Améstica, Juan P Cruces, Franco Díaz

Unidad de Paciente Crítico Pediátrico, Departamento de Pediatría, Hospital El Carmen Dr. Luis Valentín Ferrada, Santiago, Chile. · Laboratory of Translational Research in Critical Care, Center for Research on Pandemic Resilience, Faculty of Life Sciences, Universidad Andrés Bello, Santiago, Chile.

Observational

Key points

From the paper's conclusion
  • In PARDS, the Flow/CRS ratio is associated with measured strain rate but exhibits systematic bias, precluding direct interchangeability. Flow/CRS may serve as a pragmatic bedside marker reflecting deformation-velocity behavior. Prospective validation in larger and more heterogeneous cohorts is required.

Abstract

OBJECTIVES: To determine the relationship between the ratio of peak inspiratory flow and respiratory system compliance (Flow/CRS) and strain rate in cases of pediatric acute respiratory distress syndrome (PARDS). DESIGN: Secondary analysis of observational cohort data collected in 2022. SETTING: Single-center tertiary PICU in Chile. PATIENTS: Thirty-one mechanically ventilated patients with early PARDS, 15 years or younger. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: All patients were supported with volume-controlled ventilation during measurement of pulmonary mechanics, including tidal volume (Vt), inspiratory time (Ti), inspiratory flow, and respiratory system compliance (CRS). End-expiratory lung volume (EELV) was assessed using the nitrogen multiple-breath wash-in/washout method. Lung strain (Vt/EELV), strain rate (lung strain/Ti, s-1), and the Flow/CRS ratio ([L·min-1]/[mL·cm H2O-1]) were calculated. The median (interquartile range [IQR]) strain rate was 0.56 s-1 (IQR, 0.40-0.73 s-1) and the median Flow/CRS ratio was 0.94 (IQR, 0.77-1.20). In the complete dataset, Flow/CRS ratio demonstrated a moderate positive correlation with measured strain rate (Spearman, ρ = 0.42; 95% CI, 0.08-0.67; p = 0.009). Linear regression confirmed a proportional relationship (R2 = 0.17; p = 0.022), but the Bland-Altman analysis showed systematic bias (mean difference, -0.43 ± 0.29 s-1) with 95% limits of agreement from -0.99 to 0.14 s-1. Sensitivity analysis excluding three outliers (leaving data from 28 patients) demonstrated a stronger association (ρ = 0.63; p = 0.0018) and improved model fit (R2 = 0.41; p < 0.001), with the following equation: strain rate = 0.61·(Flow/CRS) + 0.01. CONCLUSIONS: In PARDS, the Flow/CRS ratio is associated with measured strain rate but exhibits systematic bias, precluding direct interchangeability. Flow/CRS may serve as a pragmatic bedside marker reflecting deformation-velocity behavior. Prospective validation in larger and more heterogeneous cohorts is required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers