Device-Patient Interface Air Leaks During Noninvasive Ventilation: Single-Center Pediatric Experience and Outcomes, 2018-2023.
Nathalie El-Hawli, Francis-Olivier Beauchamp, Sandrine Essouri, Michaël Sauthier
Faculty of Medicine, Université de Montréal, Montréal, QC, Canada.
Key points
From the paper's conclusion- In our center, 2018-2023, high air leaks were frequent during NIV and associated with fewer VFDs. As a potentially modifiable factor, further prospective research is needed to assess the impact of air leaks on outcomes.
Abstract
OBJECTIVES: Air leaks are common during noninvasive ventilation (NIV) of children in the PICU. We aimed to describe our experience with NIV and study the association between the occurrence of air leaks and clinical parameters, and the median (95% CI) of ventilator-free days (VFDs). DESIGN: Single-center retrospective cohort, 2018-2023, identified in local health databases. SETTING: A quaternary children's center PICU in Montréal, Quebec, Canada. PATIENTS: All pediatric patients admitted to the PICU and ventilated with a dual-limb NIV circuit (2018-2023). Only the first 6 hours of NIV per admission were analyzed; repeated admissions were included as separate encounters. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among 1460 encounters (1292 distinct patients), the median (interquartile range [IQR]) of air leak occurrence was 74% (IQR, 62-83%). Younger age was associated with a higher occurrence of air leaks (p < 0.001): 79% (IQR, 71-86%) in 681 infants 0-6 months old vs. 70% (IQR, 56-82%) in 328 older infants and toddlers 7-24 months old (n = 328, 22%) vs. 66% (IQR, 49-78%) in 451 preschool and school-aged children older than 24 months. A 10% increase in median air leak occurrence during the first 6 hours of NIV was associated with 0.6 fewer VFDs (slope estimate, -0.06 [95% CI, -0.10 to -0.01]). Lower air leaks were associated with higher peak airway pressures (slope estimate, -0.79 [95% CI, -1.44 to -0.15]), higher respiratory rate (slope estimate, -0.19 [95% CI, -0.35 to -0.03]), and greater weight (slope estimate, -0.40 [95% CI, -0.54 to -0.26]). CONCLUSIONS: In our center, 2018-2023, high air leaks were frequent during NIV and associated with fewer VFDs. As a potentially modifiable factor, further prospective research is needed to assess the impact of air leaks on outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adherence to Non-Invasive Ventilation in a Provincial Cohort of Children.Chest · 2026
- Comparing the Efficacy of Negative-Pressure Ventilation to Noninvasive, Positive-Pressure Ventilation in Children With Acute Respiratory Failure.Respiratory care · 2026
- Comparison of Three Non-invasive Ventilation Interfaces in Preterm and Term Neonates: A Retrospective Cohort Study.Journal of visualized experiments : JoVE · 2026
- Ventilator-circuit configurations for noninvasive ventilation in infants with acute respiratory failure: a randomized crossover trial.Critical care (London, England) · 2026
- Non-invasive Neurally Adjusted Ventilatory Assist (NIV-Nava): Four-Year Experience in a Level III Neonatal Intensive Care Unit.Cureus · 2026
- Hemodynamic and respiratory effects of non-invasive ventilation modalities in very preterm infants: a randomized crossover trial.Pediatric research · 2026