Optimizing irrigation and improving surgical operability in UBE: Technical note and preliminary results of a new guiding device.
Shu Nakamura, Zenya Ito, Mitsuto Taguchi
Department of Orthopedic Surgery, Aichi Spine Hospital, Aichi, Japan. · Department of Anesthesiology, Aichi Spine Hospital, Aichi, Japan.
Key points
From the paper's conclusion- This preliminary study suggests that the guiding device may attenuate IFP elevation during UBE.
Abstract
Excessive irrigation fluid pressure (IFP) is a recognized concern in unilateral biportal endoscopy (UBE), although troublesome bleeding may still occur. In addition, delayed washout of bone resection debris often necessitates extensive muscle cauterization and fascial incisions as countermeasures. A guiding device equipped with longitudinal grooves and a functional handle was applied at the working portal. IFP was measured and compared among full-endoscopic laminotomy, percutaneous stenoscopic lumbar decompression, and UBE performed with and without the guiding device to assess its efficacy. The washout time was 5.09 seconds without the guiding device and 0.69 seconds with the guiding device, indicating a significantly shorter washout time when the guiding device was used. With drill insertion, UBE without the guiding device indicated the highest IFP across all water levels, with the steepest increase as the water level was raised. In contrast, UBE with the guiding device indicated lower IFP, with pressure elevation intermediate between full-endoscopic laminotomy and percutaneous stenoscopic lumbar decompression. Without instrument insertion, UBE without the guiding device indicated high IFP even at low water levels, with a steep increase as the water level was raised, whereas other procedures indicated minimal IFP elevation. This preliminary study suggests that the guiding device may attenuate IFP elevation during UBE. Even with minimal dilation, the device facilitated adequate drainage, resulting in improved washout time and enhanced visualization. Insertion and removal of surgical instruments also became smoother.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Gravity-Based vs. Pump-Assisted Irrigation in Unilateral Biportal Endoscopic Decompression for Lumbar Spinal Stenosis: Effects on Operative Efficiency, Clinical Outcomes, and Complications.Medicina (Kaunas, Lithuania) · 2026
- What triggers intraoperative blood pressure/heart rate surges and postoperative hypertonia during unilateral biportal endoscopy?BMC anesthesiology · 2026
- Unilateral biportal endoscopy in lumbar spine surgery: current evidence, learning curve, technical considerations, and complication preventionEgyptian Journal of Neurosurgery · 2026
- Pressure-modulated dural repair during unilateral biportal endoscopic spine surgery: technique description and preliminary feasibility report.Frontiers in surgery · 2026
- First European experience with LithoVue™ Elite: Multicentre end-user experience and feedback.Central European journal of urology · 2026
- Intrarenal pressure during ex-vivo flexible ureteroscopy: a pilot experimental study in cadaveric kidneys.World journal of urology · 2026