Bacterial contamination of surgical blades, suction tips, and iodophor drapes in primary joint arthroplasty: A prospective cohort study.
Guang-Hua Liang, Talante Juma, Heng Liu
Department of Orthopedics, Peking University First Hospital, Beijing, China.
Key points
From the paper's conclusion- Overall contamination rates differed significantly among device types (GEE Wald χ2 = 15.14, df = 4; P = .004), although no individual device differed significantly from the control blade; for skin-incision blades, OR = 3.65 (95% CI, 0.73-18.27; P = .116).
Abstract
Intraoperative bacterial contamination may contribute to microbial transmission during joint arthroplasty, but its distribution across surgical devices and clinical significance remain uncertain. This study aimed to characterize intraoperative bacterial contamination, compare contamination-positive and contamination-negative patients, evaluate contamination across device types, and assess postoperative infection outcomes. This prospective cohort study included 127 patients undergoing primary joint arthroplasty between February 2016 and April 2017. Samples from an unused control blade, skin-incision blade, deep-tissue blade, povidone-iodine-impregnated drape, and suction tip underwent aerobic and anaerobic culture. Patients were classified according to whether at least 1 specimen yielded bacterial growth. Patient-level characteristics were compared between contamination-positive and contamination-negative groups. Device-specific contamination was compared using generalized estimating equations (GEE) to account for within-patient correlation. Patients were followed for 24 to 38 months. A total of 13 of 127 patients (10.2%) had at least 1 positive culture. After exclusion of suspected sampling or transport contamination, positivity rates were 1.7% for control blades, 5.9% for skin-incision blades, 0.8% for deep-tissue blades, 2.5% for povidone-iodine-impregnated drapes, and 2.6% for suction tips. Patient-level demographic, surgical, and comorbidity characteristics did not differ significantly between groups. Overall contamination rates differed significantly among device types (GEE Wald χ2 = 15.14, df = 4; P = .004), although no individual device differed significantly from the control blade; for skin-incision blades, OR = 3.65 (95% CI, 0.73-18.27; P = .116). No surgical-site infections, periprosthetic joint infection, or deep soft-tissue infection occurred during follow-up. Intraoperative bacterial contamination occurred across multiple surgical devices despite standardized perioperative measures, with overall contamination rates differing by device type. Skin-incision blades had the highest observed positivity rate, but no device showed a statistically significant increase versus the control blade. The absence of postoperative infection underscores the distinction between microbiological contamination and clinical infection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating the impact of povidone-iodine irrigation on microbial contamination in reverse total shoulder arthroplastyBone and Joint Research · 2026
- Currently applied sonication protocols for the detection of implant-associated infections in orthopaedics: a scoping reviewJournal of Clinical Microbiology · 2026
- Optimizing Intraoperative Tissue Sampling in Hip and Knee Periprosthetic Joint Infection: Deep Bone Provides Higher Culture Yield in One-Stage Exchange.The Journal of arthroplasty · 2026
- Infectious complications and microbiological patterns following Versius assisted robotic surgery: a cohort study from Pakistan.Journal of robotic surgery · 2026
- Beyond the patient: Inanimate objects as reservoirs for potential pathogenic bacteria and antimicrobial resistance patterns in hospital wards, a cross-sectional study from Goba Referral Hospital.BMC microbiology · 2026
- Complementary Time-Kill Activity Displayed by Povidone-Iodine and Hydrogen Peroxide Against Shoulder Arthroplasty-Associated Pathogens, Envisaging Intraoperative Irrigation.Pharmaceuticals (Basel, Switzerland) · 2026