Coronary artery disease

The perforation triad as a recognition-and-response pattern for balloon- or stent-related Ellis II-III coronary artery perforation during percutaneous coronary intervention.

Emrah Acar, Melike Acar, İbrahim Dönmez, Servet İzci, Yilmaz Güneş, İbrahim Akin İzgi, Cevat Kirma

Department of Cardiology, Abant İzzet Baysal University Medical School, Bolu. · Department of Cardiology, Health Sciences University, Kartal Koşuyolu Cardiovascular Research and Training Hospital, Istanbul, Turkey.

Observational · n=41

Key points

From the paper's conclusion
  • The perforation triad is a plausible recognition pattern for balloon- or stent-related Ellis II-III CAP. Because of retrospective sampling, selected controls, and incorporation bias, it should not be interpreted as a validated diagnostic rule or as evidence of real-world specificity; prospective inflation-level validation is required.

Abstract

OBJECTIVE: Coronary artery perforation (CAP) is a rare but potentially catastrophic complication of percutaneous coronary intervention (PCI). We describe a prespecified candidate recognition pattern - the perforation triad - that may help operators identify an evolving perforation during inflation. METHODS: In this single-center retrospective matched case-control study, 9865 PCI procedures performed between 2020 and 2025 were screened. Forty-one balloon- or stent-related Ellis II-III CAP cases (0.42%) were matched 1: 1 by age, sex, American College of Cardiology/American Heart Association lesion class, and rotational atherectomy use with uncomplicated PCI controls, each contributing one stage-matched index inflation. The triad - chest or back pain during inflation, abrupt balloon-waist disappearance without balloon rupture, and ventricular extrasystole temporally linked to inflation - was prespecified before data abstraction and adjudication. Prespecified descriptive analyses covered the three components, their pairwise combinations, and component-count thresholds; no threshold optimization was undertaken. RESULTS: Among CAP cases, components were present in 78.0, 85.4, and 73.2%, respectively; the complete triad in 28 of 41 cases (68.3%; 95% confidence interval: 51.9-81.9) and in 0 of 41 selected control inflations. Control inflations meeting the pattern fell as more components were required (≥1, 20 of 41; ≥2, 10 of 41; triad, 0 of 41), with case-level sensitivity of 87.8, 80.5, and 68.3%. Tamponade requiring drainage occurred in 29.3%, and in-hospital mortality was 7.3%. CONCLUSION: The perforation triad is a plausible recognition pattern for balloon- or stent-related Ellis II-III CAP. Because of retrospective sampling, selected controls, and incorporation bias, it should not be interpreted as a validated diagnostic rule or as evidence of real-world specificity; prospective inflation-level validation is required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers