Development and Validation of a Reproducible Cross-Species Liver Machine Perfusion Platform in Rats and Mice.
Greta N Cywińska, Joshua S Badshah, Shuling Han, Ryan M Lee, Tetsuya Tajima, Pamela Emengo, Fabiana Aellos, Bo Liu,
From the Division of Abdominal Transplantation, Department of Surgery, Stanford University School of Medicine, Stanford, California. · Division of Pediatric Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, California.
Key points
From the paper's conclusion- We developed a modular rat-mouse liver machine perfusion platform built around a shared extracorporeal circuit backbone with interchangeable cannulation interfaces, continuous inflow pressure monitoring, and a compact dry thermal-bead bath supporting benchtop subnormothermic and normothermic studies as well as cold-room hypothermic deployment.
Abstract
Ex vivo liver machine perfusion is increasingly used for graft assessment and reconditioning, but reproducible small-animal platforms remain limited. We developed a modular rat-mouse liver machine perfusion platform built around a shared extracorporeal circuit backbone with interchangeable cannulation interfaces, continuous inflow pressure monitoring, and a compact dry thermal-bead bath supporting benchtop subnormothermic and normothermic studies as well as cold-room hypothermic deployment. Performance was assessed by methylene blue perfusion mapping with pixel-based quantification and by blinded Suzuki histologic injury scoring. In mice, the portal cannulation site within the superior mesenteric vein-portal segment determined the completeness of whole-organ perfusion; positioning the cannula distal to the gastric/splenic/pancreatic tributary and proximal to the inferior pancreaticoduodenal vein ensured homogeneous lobar perfusion. In rats, single portal inflow left peripheral lobar regions relatively underperfused, whereas dual portal venous plus hepatic arterial inflow produced the most uniform perfusion (perfused surface area 58-75% vs. 100%). Histology showed preserved architecture on liver biopsies, with total Suzuki scores of 0-1 of 12 across procurement baseline, immediate perfusion, and cold storage plus reperfusion groups. Reproducible whole-organ perfusion demonstrated depends on species-specific vascular access. The current platform was validated for perfusion adequacy and short-term structural preservation; metabolically sustained support and functional viability remain to be demonstrated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine Perfusion in Liver Transplantation: A Systematic Review and Meta-Analysis Comparing Outcomes with Conventional Static Cold Storage.Journal of clinical medicine · 2026
- The perfused liver utilisation study (PLUS): challenges and innovation in the evaluation of an emerging technology.Transplant international : official journal of the European Society for Organ Transplantation · 2026
- Organ procurement organization utilization of portable hypothermic oxygenated machine perfusion in liver transplantation: The first US experienceSurgery · 2026
- Liver Machine Perfusion: Past, Present and Future DirectionsBiomedicines · 2025
- Machine Perfusion Preservation as a Platform for Advanced Liver SurgeryArtificial Organs · 2026
- Dysregulated coagulation in normothermic machine perfusion of gene-edited pig liver ex vivo: molecular mechanisms, genetic engineering strategies and implications for clinical translation.Frontiers in transplantation · 2026