Infectious Adverse Events in Pediatric Paracorporeal Ventricular Assist Devices: An Analysis of the Advanced Cardiac Therapies Improving Outcomes Network (ACTION) Registry.
Neha Bansal, Lara Danziger-Isakov, Madeleine Townsend, Rashmita Naorem, Muhammad Farrukh Shezad, Lydia K Wright, Charles Bergstrom, E Kevin Hall,
From the Division of Pediatric Cardiology, Children's Hospital at Montefiore, Bronx, New York. · Division of Infectious Disease, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
Key points
From the paper's conclusion- This study aimed to identify risk factors for IAEs from the Advanced Cardiac Therapy Improving Outcomes Network (ACTION) registry.
Abstract
Infectious adverse events (IAEs) are common in children supported with paracorporeal ventricular assist devices (VADs). This study aimed to identify risk factors for IAEs from the Advanced Cardiac Therapy Improving Outcomes Network (ACTION) registry. We conducted a retrospective study including pediatric patients supported with paracorporeal VADs. Patients were stratified by device type (paracorporeal pulsatile [PP], paracorporeal continuous [PC], or overlapping). Kaplan-Meier analysis, the log-rank test, and Cox proportional hazards models evaluated factors associated with survival and time to first IAE. Among 812 patients on paracorporeal VADs, 270 (33.2%) experienced IAEs (479 events). Localized non-device IAEs were most common (40.9%). Patients with IAEs were younger, had lower body surface area (BSA), were more likely to require mechanical ventilation pre-implant, and had longer VAD support duration. Freedom from IAEs was lower in patients with PC devices or overlapping support (p = 0.0081). Survival was worse after IAEs (p = 0.0096). Overlapping device support was independently associated with an increased risk of IAE (hazard ratio [HR]: 1.387; p = 0.0354), while larger BSA was protective (HR: 0.542; p = 0.0264). IAEs remain common in children on VAD support and are associated with mortality, with device overlaps and smaller patient size as independent risk factors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prevalence and Risk Factors for Ventricular Assist Device-Associated Infection in Children: An Analysis ACTION Study.Artificial organs · 2026
- Longer-Term Ventricular Assist Devices in Children: 10-Year Retrospective Analysis of Society of Thoracic Surgeons' PEDIMACS.Journal of the American Heart Association · 2026
- Impact Of Ventricular Assist Device Use On Pediatric Heart Transplant Outcomes In A Linked Cohort Of The Advanced Cardiac Therapies Improving Outcomes Network (ACTION) And Pediatric Heart Transplant Society (PHTS) Databases.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2026
- Current Global Trends and Challenges of Pediatric Ventricular Assist Device Programs: An ACTION Collaborative Survey.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Clinical characteristics and outcomes of left ventricular assist device (LVAD) infections: Could driveline infections be a predictor of deep-seated infections?BMC infectious diseases · 2026
- Infections in mechanical circulatory support.Frontiers in cardiovascular medicine · 2026