Circuit-Directed Nitric Oxide in Anticoagulation-Contraindicated Adult Extracorporeal Membrane Oxygenation: A Single-Center Case Series.
Sajid Kadir, Sumeet Jain, Firas Madbak, Matthew Kochuba, Douglas Kirk, Nicole Clay, Joseph Shiber
From the Department of Medicine, University of Florida College of Medicine-Jacksonville, UF Health Jacksonville, Jacksonville, Florida. · Department of Surgery, University of Florida College of Medicine-Jacksonville, UF Health Jacksonville, Jacksonville, Florida.
Key points
From the paper's conclusion- We conducted a single-center retrospective case series of adult extracorporeal membrane oxygenation (ECMO) patients treated between January 1, 2025, and May 31, 2026, who received circuit-directed NO while systemic anticoagulation and antiplatelet therapy were withheld due to clinically significant bleeding risk.
Abstract
Oxygenator thrombosis is a major complication during extracorporeal membrane oxygenation (ECMO), but systemic anticoagulation may be contraindicated by active hemorrhage, recent surgery, intracranial injury, or severe coagulopathy. Circuit-directed nitric oxide (NO) delivered into the oxygenator sweep gas may provide localized antiplatelet activity at the blood-circuit interface without intentionally producing systemic anticoagulation. We conducted a single-center retrospective case series of adult extracorporeal membrane oxygenation (ECMO) patients treated between January 1, 2025, and May 31, 2026, who received circuit-directed NO while systemic anticoagulation and antiplatelet therapy were withheld due to clinically significant bleeding risk. Nitric oxide was delivered at 20 ppm via a NOxBOXi system connected to the oxygenator sweep-gas pathway. Ten patients received circuit-directed NO: three venovenous, six venoarterial, and one venopulmonary arterial, for durations of 2-72 days. No patient required oxygenator exchange for thrombosis, gas-exchange failure, progressive trans-oxygenator pressure-gradient elevation, or hemolysis. The trans-oxygenator pressure gradient remained below 50 mm Hg in all patients. Maximum methemoglobin ranged from 1.0% to 3.4%, and no patient required NO discontinuation. Nine of 10 patients survived to decannulation. In this small uncontrolled series, circuit-directed NO was feasible and not associated with NO-attributable safety events or oxygenator exchange; efficacy cannot be inferred.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dose-dependent effects of nitric oxide on erythrocyte membranes and platelet aggregation in an ex vivo model of cardiopulmonary bypass: an experimental studyAnnals of critical care · 2026
- Anticoagulant effects of nafamostat administered via central venous catheter versus the ECMO circuit in adults receiving ECMO support.Frontiers in cardiovascular medicine · 2026
- Bridging the Evidence Gap: A Call to Action for Anticoagulation Research in Pediatric Burned Patients on Extracorporeal Membrane Oxygenation.Journal of burn care & research : official publication of the American Burn Association · 2026
- Association Between Systemic Anticoagulation and Outcomes in Patients With Acute Respiratory Distress Syndrome Receiving Venovenous Extracorporeal Membrane Oxygenation: Insights From a Multicenter Propensity-Weighted StudyCritical Care Medicine · 2026
- Shear-Induced Dysregulation of Haemostasis During Extracorporeal Membrane Oxygenation: From Cells to CircuitEuropean Journal of Heart Failure · 2025
- Effects of inhaled nitric oxide during mechanical circulatory support: a prospective pilot study.Heart and vessels · 2026