Sweep Frequency Impedance Measures of Otosclerosis.
Hisashi Sugimoto, Teruki Toya, Yasunori Donjo, Ryosei Motoo, Manabu Inaba, Goki Nagasaki, Tomokazu Yoshizaki, Michio Murakoshi
Department of Otolaryngology-Head and Neck Surgery, Kanazawa University Graduate School of Medical Science, Kanazawa, Japan. · Faculty of Engineering, Graduate Faculty of Interdisciplinary Research, University of Yamanashi, Yamanashi, Japan.
Key points
From the paper's conclusion- The findings suggest that the SFI meter may provide superior diagnostic accuracy compared with conventional testing modalities. Although no statistically significant correlations were identified, the direction of the observed associations was consistent with the expected biomechanical model, in which increased stiffness would be associated with higher resonance frequency, reduced SPL modulation, and a larger AB gap. SFI measurements may offer a means to estimate the degree of stapes footplate fixation preoperatively.
Abstract
OBJECTIVE: This study aimed to validate the preoperative diagnosis of otosclerosis using a Sweep Frequency Impedance (SFI) meter. In addition, it investigated whether the measurement values obtained from the SFI meter correlate with the perceived stiffness of the stapes footplate. STUDY DESIGN: Retrospective cohort study. SETTING: A tertiary referral center. PATIENTS: Thirty-seven ears were surgically confirmed between September 2020 and December 2023 at Kanazawa University Hospital and affiliated institutions-22 diagnosed with otosclerosis and 15 with ossicular discontinuity. INTERVENTIONS: (1) The diagnostic performance of SFI, tympanometry, the Carhart notch, and CT demineralization imaging. (2) Evaluation of the correlation between stapes footplate stiffness and SFI meter parameters, specifically the change in sound pressure level (ΔSPL) and the resonance frequency (RF). MAIN OUTCOME MEASURES: Correct diagnosis rate of SFI. Correlation between preoperative audiometric data and SFI meter parameters (ΔSPL and RF). Correlation between preoperative hearing data and the perceived stiffness of the stapes footplate. RESULTS: The SFI meter demonstrated the highest diagnostic accuracy, with a correct diagnosis rate of 0.91, followed by the Carhart notch at 0.73 and CT imaging and tympanometry at 0.459. No statistically significant correlations were observed between preoperative audiometric data and SFI meter parameters or the perceived stiffness of the stapes footplate. CONCLUSIONS: The findings suggest that the SFI meter may provide superior diagnostic accuracy compared with conventional testing modalities. Although no statistically significant correlations were identified, the direction of the observed associations was consistent with the expected biomechanical model, in which increased stiffness would be associated with higher resonance frequency, reduced SPL modulation, and a larger AB gap. SFI measurements may offer a means to estimate the degree of stapes footplate fixation preoperatively.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Preoperative air-bone gap predicts thick stapes footplate requiring microdrill fenestration in otosclerosis.American journal of otolaryngology · 2026
- Symons and Fanning Classification in Otosclerosis and its Relation to Audiologic Parameters, Stapes Footplate Thickness, and Round Window Involvement.Audiology & neuro-otology · 2026
- The use of high-resolution ct (HRCT) of the temporal bone for accurate preoperative prediction of stapes prosthesis length in patients with otosclerosisThe Egyptian Journal of Otolaryngology · 2026
- Photon-counting CT for preoperative assessment of stapes footplate fixation in otosclerosis.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Comparison of cone beam computed tomography multiplanar reconstruction in the plane of stapes and the lateral semicircular canal for the diagnosis of otosclerosis.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Evaluating the Utility of Preoperative CT Imaging for Stapedectomy.The Laryngoscope · 2026