Prospective single-arm study of gastric surgery in experimental animals assisted by Kangduo surgical robot.
Songtao Yu, Yuliuming Wang, Tianyi Ma, Tianyu Qiao, Hao Zhang, Yunxiao Liu, Chunlin Wang, Wenyang Li,
Department of Colorectal Cancer Surgery, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
Key points
From the paper's conclusion- The feasibility, efficacy, and safety of the SR2000 were verified in animal experiments, and ergonomically optimized design have the potential for clinical dissemination.
Abstract
OBJECTIVE: To investigate the feasibility, efficacy, and safety of gastric surgery in experimental animals assisted by the domestic Kangduo Surgical Robot 2000 (SR2000). METHODS: Eight porcine models were prospectively enrolled between August and December 2023 at Harbin SAGEBOT Intelligent Medical Animal Experiment Center. Preoperative baseline characteristics, intraoperative physiological parameters, surgical procedure, and postoperative assessments and investigations were recorded to compare the feasibility, efficacy, and safety evaluation indexes of experimental animals in the perioperative period. The primary endpoint was surgical success rate. The secondary endpoints were operative workflow parameters, intraoperative blood loss, postoperative laboratory changes, perioperative adverse events, and surgeon workload assessed using the NASA-TLX instrument. RESULTS: In eight experimental pig models, the SR2000 successfully assisted in the completion of partial gastrectomy. All surgeries were completed according to plan, with no intermediate open or intraoperative complications, and the perioperative survival rate of animals was 100%. The mean operation time of partial gastrectomy was 76.75 min (range: 50-105 min), and the positioning time was 6-17 min. Intraoperative bleeding was ≤5 ml in all the animals, and some animals showed elevated white blood cell counts and neutrophil counts (Neu) on the first day of the postoperative period. The liver and kidney function indexes (alanine aminotransferase, blood urea nitrogen, creatinine) were not significantly abnormal before and after surgery. The anastomosis healed well without complications such as infection and anastomotic fistula. CONCLUSION: The feasibility, efficacy, and safety of the SR2000 were verified in animal experiments, and ergonomically optimized design have the potential for clinical dissemination.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Safety and efficacy of traction robot-assisted endoscopic submucosal dissection for early gastric cancer: a randomized pilot trialEndoscopy · 2025
- Bedside assistant models in robotic abdominal and pelvic surgery: a systematic review of operative efficiency, training exposure, and perioperative safety.Journal of robotic surgery · 2026
- Robotic-assisted versus laparoscopic gastrectomy in a low-incidence Nordic country: A single-center retrospective study.Scandinavian journal of surgery : SJS : official organ for the Finnish Surgical Society and the Scandinavian Surgical Society · 2026
- Short-term outcomes of robotic-assisted distal pancreatectomy using domestic KangDuo Surgical Robot-2000 System versus Da Vinci Xi system: a two-center prospective observational cohort study.Surgical endoscopy · 2026
- Robot-assisted gastrectomy for locally advanced gastric cancer and complex clinical scenarios: technical evolution, evidence gaps, and future directions.Journal of robotic surgery · 2026
- Comparison of the efficacy of different models of KangDuo surgical robots and the da Vinci surgical robots in partial nephrectomy of RENAL score ≤9 tumors.Translational andrology and urology · 2026