American journal of medical quality : the official journal of the American College of Medical Quality

Electronic Health Record-Embedded Structural Interventions to Improve Sepsis Bundle Quality Measure Performance: A Quality Improvement Initiative at a Veterans Affairs Medical Center.

Justin C Zhang, Kavon Javaherian, Josue Zapata, Ryan Duffy, Chuanyi M Lu, Erika Price, Helena Snowden, Anil Agarwal,

Department of Medicine, University of California San Francisco, San Francisco, CA. · Division of Hospital Medicine, Department of Medicine, Durham VA Medical Center, Durham, NC.

Key points

From the paper's conclusion
  • EHR-embedded structural interventions produced sustained SEP-1 improvement without impacting laboratory utilization or mortality, offering a reproducible model for improvement through systems redesign rather than education alone.

Abstract

BACKGROUND: Though emphasized as a quality metric, sepsis quality measure (SEP-1) compliance remains low nationwide. Electronic health record (EHR)-based interventions show promise, but few have examined EHR laboratory reference value misconfiguration as a distinct driver of noncompliance. LOCAL PROBLEM: The San Francisco Veterans Affairs, a 110-bed tertiary care center, recorded 3 consecutive quarters of SEP-1 composite performance in the lowest national quintile, nadiring at 31.5%. METHODS: A multidisciplinary team applied LEAN-A3 methodology to identify root causes of low SEP-1 performance and design targeted countermeasures. The primary outcome was the percentage of suspected sepsis patients with a serum lactate >2.0 mmol/L who received a repeat lactate within 6 hours. Balancing measures included unnecessary repeat lactates and sepsis mortality. INTERVENTIONS: Three EHR-based interventions were implemented between August and November 2025: (1) an Emergency Department Sepsis order-set embedding dual time-spaced lactate orders; (2) a structured Sepsis Evaluation Note template; and (3) a clinical decision support alert for patients with serum lactate >2.0 mmol/L, implemented to address a laboratory reference range misconfiguration. RESULTS: Postintervention lactate reassessment compliance rose 14 percentage points (54%-68%), meeting Institute for Healthcare Improvement criteria for special cause variation. Facility 12-month rolling performance rose from 31.5% (lowest quintile) to 64.7% (middle quintile), reaching a quarterly high of 74.3%. No increase in unnecessary repeat lactates or sepsis mortality was detected. CONCLUSIONS: EHR-embedded structural interventions produced sustained SEP-1 improvement without impacting laboratory utilization or mortality, offering a reproducible model for improvement through systems redesign rather than education alone.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers