Journal of cataract and refractive surgery

Database-optimized versus manufacturer recommended lens constants for the prediction of postoperative refractive error following cataract surgery.

Seth Michel Pantanelli, Luke Rebenitsch, John A Vukich, Sergio Sanchez, Julie M Schallhorn

Department of Ophthalmology, Penn State College of Medicine, Hershey, PA, USA . · ClearSight LASIK and Lens, Oklahoma City, OK, USA.

Observational · n=14,172

Key points

From the paper's conclusion
  • Lens constant optimization using the Veracity surgical planner can result in significant reduction in prediction error. Using these database-optimized lens constants over manufacturer recommended ones may improve refractive outcomes after cataract surgery for most types of IOLs and eyes.

Abstract

PURPOSE: To compare refractive outcomes when Veracity database-optimized (Dopt) or manufacturer-suggested (Mfr) lens constants are used to perform IOL power calculations. DESIGN: Retrospective database study across the United States. SETTING: Database-optimized lens constants (Dopt) were validated in an independent dataset from 268 surgeons. METHODS: This retrospective database validation study analyzed cataract surgery cases planned using Veracity between November 2023 and December 2025. Dopt, previously derived from user-reported outcomes through October 2023, were evaluated against manufacturer-recommended (Mfr) constants in an independent validation dataset. Eligible eyes had their predicted postoperative spherical equivalent (SE) calculated using anterior and posterior keratometry, Barrett Universal II formula, and either Dopt and Mfr lens constants. RESULTS: In total, 14,172 eyes from 14,172 patients were included in this study. Mean prediction error and mean absolute error of the SE was significantly improved with the Dopt constant (-0.004 ± 0.424 D and 0.320 D, respectively) compared to Mfr group (0.167 ± 0.431 D and 0.353 D, respectively, p<0.0001 ). The proportions of eyes with PE within 0.25, 0.50, 0.75 and 1.00 D were also significantly higher for the Dopt constant (50%, 80%, 93% and 97%, respectively) compared to Mfr group (44%, 75%, 91% and 97%, respectively, p<0.0001 ). The use of Dopt constant also resulted in a lower MPE for most subgroups and for 86% of the IOL models assessed in this study. CONCLUSION: Lens constant optimization using the Veracity surgical planner can result in significant reduction in prediction error. Using these database-optimized lens constants over manufacturer recommended ones may improve refractive outcomes after cataract surgery for most types of IOLs and eyes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Database-optimized versus manufacturer recommended lens constants for the prediction of postoperative refractive error following cataract surgery — Science Skim