Journal of cataract and refractive surgery

Clinical outcomes according to the functional classification of intraocular lenses based on depth-of-field after myopic Laser in situ Keratomileusis.

Jiyoung Emily Lee, Hyun Seung Kim, Eun Chul Kim

Department of Ophthalmology, Bucheon St. Mary's Hospital, The Catholic University of Korea, Seoul, Republic of Korea. · Department of Ophthalmology, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Republic of Korea.

Observational · n=90

Key points

From the paper's conclusion
  • In selected post-myopic LASIK eyes, expected DOFi-based functional differences remained evident after correction of residual refractive error. Barrett True-K TK and Haigis TK showed generally comparable refractive performance. These findings indicate that DOFi-based functional classification remains clinically relevant in eyes with previous myopic LASIK.

Abstract

PURPOSE: To compare refractive predictability and functional visual outcomes among three depth-of-field (DOFi)-based intraocular lens (IOL) categories in eyes with previous myopic laser in situ keratomileusis (LASIK). SETTING: A single-center, university-affiliated hospital. DESIGN: Retrospective comparative cohort study. METHODS: 90 eyes of 45 patients who underwent bilateral cataract surgery after myopic LASIK were classified according to implanted IOL type: Full-DOFi Smooth (Tecnis Synergy), Partial-DOFi Enhanced (Eyhance), and Partial-DOFi Extended IOLs (PureSee). Distance-corrected visual acuity, monocular distance-corrected defocus curves, DOFi at 0.2 logMAR, refractive predictability with Barrett True-K TK and Haigis TK after IOL-specific optimization or mean prediction error zeroing, and patient-reported satisfaction were evaluated 3 months postoperatively. RESULTS: Corrected distance and intermediate visual acuities were comparable among groups (P = .967 and .780), whereas corrected near visual acuity differed (P < .001), favoring Full-DOFi Smooth, followed by Partial-DOFi Extended and Partial-DOFi Enhanced. DOFi was 3.22, 2.23, and 1.56 D, respectively. Prediction errors within ±0.50 D ranged from 76.7% to 83.3% with Barrett True-K TK and 70.0% to 73.3% with Haigis TK. Eyetemis analysis showed no trueness differences; Barrett True-K TK showed better precision and accuracy only in the Full-DOFi Smooth group. Near-vision satisfaction differed among groups, whereas pairwise glare/halo differences were not significant. CONCLUSION: In selected post-myopic LASIK eyes, expected DOFi-based functional differences remained evident after correction of residual refractive error. Barrett True-K TK and Haigis TK showed generally comparable refractive performance. These findings indicate that DOFi-based functional classification remains clinically relevant in eyes with previous myopic LASIK.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers