OpenEvidence versus Six Leading Large Language Models in Refractive Surgery: Does Curated Medical Evidence Confer an Advantage?

Avi Wallerstein, Mathilde Gallant, Mathieu Gauvin

Department of Ophthalmology and Visual Sciences, McGill University, Montreal, QC, Canada. · LASIK MD, Montreal, QC, Canada.

Computational

Key points

From the paper's conclusion
  • OpenEvidence demonstrated significantly lower accuracy than the six evaluated general-purpose LLMs and did not exceed the BCSC Self-Assessment program user benchmark on this standardized refractive surgery multiple-choice assessment. This task-specific difference was not fully explained by response-format noncompliance and should not be interpreted as direct evidence of globally inferior medical knowledge or performance in open-ended clinical applications.

Abstract

PURPOSE: To assess the accuracy of OpenEvidence relative to six leading large language models (LLMs) in answering refractive surgery multiple-choice questions, and to compare their performance with users of the American Academy of Ophthalmology (AAO) Basic and Clinical Science Course (BCSC) Self-Assessment Program. SETTING: Not applicable. DESIGN: Randomized questionnaire-based study using 225 questions from the refractive surgery section of the AAO BCSC Program. METHODS: OpenEvidence and 6 LLMs (ChatGPT-4o, ChatGPT-5, Claude, Copilot, Gemini, and Grok) answered the same set of multiple-choice questions. Their accuracy was defined as the proportion of correct responses. Performance from 1,983 BCSC Self-Assessment Program users served as a benchmark. RESULTS: OpenEvidence achieved the lowest accuracy (76%) and performed significantly worse (P<0.05) than all six general-purpose LLMs. Claude achieved the highest accuracy (92%), followed by Grok (89.8%). ChatGPT-5, Copilot, and Gemini each scored an accuracy of 88%, and ChatGPT-4o achieved 86.2%. All models' lower 95% confidence interval bounds exceeded the 60% passing threshold. The average score of BCSC Self-Assessment Program users was 77%. All general-purpose LLMs scored significantly higher than BCSC Self-Assessment Program users (P<0.05), whereas OpenEvidence did not. CONCLUSIONS: OpenEvidence demonstrated significantly lower accuracy than the six evaluated general-purpose LLMs and did not exceed the BCSC Self-Assessment program user benchmark on this standardized refractive surgery multiple-choice assessment. This task-specific difference was not fully explained by response-format noncompliance and should not be interpreted as direct evidence of globally inferior medical knowledge or performance in open-ended clinical applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

OpenEvidence versus Six Leading Large Language Models in Refractive Surgery: Does Curated Medical Evidence Confer an Advantage? — Science Skim