Visual outcomes and intraocular lens selection in highly myopic eyes.
Liangpin Li, Liyun Yuan, Xiaoyong Yuan
Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital. · School of Medicine, Nankai University, Tianjin, China.
Key points
From the paper's conclusion- To synthesize recent evidence on visual prognosis and intraocular lens (IOL) selection in highly myopic eyes undergoing cataract surgery, with emphasis on retinal phenotyping, optical biometry and IOL power calculation, capsular-zonular stability, and the use of toric and presbyopia-correcting IOLs.
Abstract
PURPOSE OF REVIEW: To synthesize recent evidence on visual prognosis and intraocular lens (IOL) selection in highly myopic eyes undergoing cataract surgery, with emphasis on retinal phenotyping, optical biometry and IOL power calculation, capsular-zonular stability, and the use of toric and presbyopia-correcting IOLs. RECENT FINDINGS: Swept-source optical biometry and newer-generation formulas have improved refractive predictability but have not eliminated error in eyes with extreme axial length or low-, zero-, and negative-power IOLs. Macular optical coherence tomography (OCT) has become central to estimating visual potential because pathologic myopia and subtle outer retinal or tractional abnormalities may constrain postoperative acuity and contrast sensitivity. High myopia alone is not an absolute contraindication to toric or presbyopia-correcting IOLs; however, candidacy should be determined by macular function, capsular stability, and the patient's tolerance for dysphotopsia and residual refractive error. Capsular tension rings appear most useful in selected eyes with axial length ≥30 mm or positioning-sensitive IOLs rather than as a routine intervention. IOL material also warrants consideration because hydrophobic acrylic lenses may reduce long-term posterior capsule opacification in highly myopic eyes. SUMMARY: Cataract surgery in high myopia requires phenotype-based planning rather than axial-length-driven lens selection. The most durable strategy integrates validated biometry, macular structure and function, capsular-zonular anatomy, realistic refractive goals, and continued retinal surveillance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Best formulas for highly myopic patients (axial length ≥26 mm) receiving cataract surgery.Current opinion in ophthalmology · 2026
- Surgical management of intraocular lens dislocation in highly myopic eyes.Frontiers in medicine · 2026
- Traumatic cataract with secondary extreme axial elongation and posterior staphyloma: a case report.BMC ophthalmology · 2026
- Implantable collamer lens surgery for high myopia: safety boundaries, vault management, and patient selection.Frontiers in ophthalmology · 2026
- Efficacy of Total Keratometric Power and Total Corneal Power on the Accuracy of 8 Modern Intraocular Lens Formulas in Highly Myopic Eyes.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Fifteen-year follow-up of implantable collamer lens surgery in high myopia: Complications, cataract surgery outcomes, and ultrastructural analysis.Advances in ophthalmology practice and research · 2026