Epiretinal Human Amniotic Membrane Overlay for Recurrent Retinal Detachment in Highly Myopic Eyes with Peripapillary Breaks over Chorioretinal Atrophy: Surgical Technique and Outcomes.
Federico Moscara, Giacomo Boscia, Pasquale Puzo, Pasquale Viggiano, Alba Chiara Termite, Ciro Borriello, Arcangelo Clemente, Ilaria Lolli,
Department of Translational Biomedicine and Neuroscience, University of Bari "Aldo Moro", Bari, Italy. · Ecclesiastical Entity - Regional General Hospital "F. Miulli", Acquaviva delle Fonti, Bari, Italy.
Key points
From the paper's conclusion- The epiretinal hAM overlay technique appears to be a safe and effective approach for sealing complex peripapillary breaks in highly myopic eyes with chorioretinal atrophy. By providing both mechanical support and a biological scaffold for tissue repair, this technique may represent a valuable surgical option in cases where conventional retinopexy is not feasible or has failed.
Abstract
PURPOSE: To evaluate the anatomical and functional outcomes of an epiretinal cryopreserved human amniotic membrane (hAM) overlay technique for the management of recurrent retinal detachment (RD) associated with peripapillary breaks in highly myopic eyes. METHODS: Retrospective interventional case series including five eyes with recurrent RD (mean axial length 30.70 ± 2.03 mm). Two eyes presented with recurrence under silicone oil (SO) tamponade, and three after prior SO removal. All eyes underwent 25-gauge pars plana vitrectomy with SO removal when present. A customized 8-9 mm hAM patch was positioned epiretinally and unrolled bimanually under perfluorocarbon liquid (PFCL). Final tamponade was achieved with SO 1000 cSt, followed by scheduled SO removal. RESULTS: Complete retinal reattachment was achieved in all cases (100%) after a single procedure and remained stable throughout follow-up. Mean best-corrected visual acuity (BCVA) improved from 1.00 ± 0.60 to 0.68 ± 0.58 logMAR at 2 months after SO removal (p = 0.068). Optical coherence tomography demonstrated stable integration of the hAM as a hyperreflective layer over the peripapillary defects. No cases of graft dislocation, proliferative vitreoretinopathy, or significant inflammatory complications were observed. CONCLUSIONS: The epiretinal hAM overlay technique appears to be a safe and effective approach for sealing complex peripapillary breaks in highly myopic eyes with chorioretinal atrophy. By providing both mechanical support and a biological scaffold for tissue repair, this technique may represent a valuable surgical option in cases where conventional retinopexy is not feasible or has failed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fibrin Glue Assisted Retinopexy over atrophic RPE in High Myopia: Case Report.Retinal cases & brief reports · 2026
- Human amniotic membrane transplantation for macular hole-associated retinal detachment: A systematic review of outcomes in refractory and complex cases.Survey of ophthalmology · 2026
- Freeze-dried human amniotic membrane graft insertion for the management of large and refractory macular holes.Eye (London, England) · 2026
- Inverted epiretinal proliferation flap with internal limiting membrane preservation for myopic macular hole retinal detachment: a case report.Frontiers in ophthalmology · 2026
- Autologous Tenon's Capsule Graft for Recurrent Retinal Detachment Associated with a Cavitary Optic Disc Anomaly following Failed Amniotic Membrane Grafting.Journal of current ophthalmology · 2026
- Plasma rich in growth factors membrane for macular holes in eyes with pathological myopia without peeling of internal limiting membraneInternational Journal of Retina and Vitreous · 2026