Analysis of Cytogenetic Detection Findings in National Radiation Worker Medical Examinations: Cytogenetic Testing Should Be Standardized (A Multicenter Data Analysis).
Gang Liu
Gansu Provincial Center for Disease Control and Prevention, Joint Laboratory of Institute of Radiology, Chinese Academy of Medical Sciences, NO.310 Donggang West Road, Lanzhou, Gansu, China 730000.
Key points
From the paper's conclusion- Considerable inter-institutional and regional variation was observed in cytogenetic detection rates. CA detected abnormalities more frequently than MN assays. Institutions with high rates warrant review of radiation protection practices and testing quality. Standardized procedures and region-specific surveillance may improve data reliability.
Abstract
OBJECTIVE: To report cytogenetic test results from the 2025 national occupational health examinations of radiation workers in China and to examine variation in abnormality rates across institutions and regions. METHODS: Data were obtained from 46 institutions for chromosomal aberration (CA) analysis, 40 for conventional lymphocyte micronucleus (MN) assays, and 6 for cytokinesis-block (CB) MN assays. Weighted abnormality rates were calculated using institution-level sample sizes as weights. The Shapiro-Wilk test assessed distribution normality. K-means clustering stratified institutions by sample size and detection rate. Regional effects were examined by comparing national data with and without Henan province. RESULTS: The weighted abnormality rate was 4.40% for CA (100,684 tests), 1.28% for conventional MN (183,910 tests), and 0.18% for CB-MN (12,096 tests). Excluding Henan reduced the CA rate to 3.20%. All three indicators deviated from normality (all P < 0.001). K-means clustering identified three institutional groups: low-abnormality (n = 32, mean 1.85%), medium-abnormality large-sample (n = 8, mean 3.76%), and high-abnormality (n = 6, mean 12.32%; maximum 25.99%). No linear association was found between sample size and abnormality rate (r = 0.128, P > 0.05). CONCLUSION: Considerable inter-institutional and regional variation was observed in cytogenetic detection rates. CA detected abnormalities more frequently than MN assays. Institutions with high rates warrant review of radiation protection practices and testing quality. Standardized procedures and region-specific surveillance may improve data reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Baseline Frequency of Chromosomal Aberrations in Control Donors: A Significant Value for Population Monitoring During the Development of the Nuclear Energy Industry-Polish Dataset.Toxics · 2026
- Assessment of occupational radiation exposure among radiology workers in Ghana using cytogenetic biomarkers and thermoluminescent dosimetry.Radiation protection dosimetry · 2026
- Biological dosimetry of chronic radiation exposure in interventional radiologists using dicentric assay and a Bayesian framework.Mutation research. Genetic toxicology and environmental mutagenesis · 2026
- Interobserver reliability and digital morphometric characterization of constitutional chromosomal heteromorphisms in clinical cytogenetics.Human genetics · 2026
- Radiation-induced chromosomal aberrations in pediatric patients with inborn errors of immunity: a G0-phase approach to assess radiosensitivity.International journal of radiation biology · 2026
- Triglyceride-glucose index and structural chromosome aberrations in medical radiation workers: a cross-sectional study with a stratified dosimetry substudy.Frontiers in public health · 2026