Plastic and reconstructive surgery. Global open

Next-generation Antigliotic Guiding Regenerative Gel Matrix (LDP-916) for Peripheral Nerve Reconstruction.

Shimon Rochkind, Arie Goldlust, Mara Almog

From the Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel. · Maxonis Ltd., Nes Ziona, Israel.

Randomised

Key points

From the paper's conclusion
  • AGRG-filled collagen conduits achieved sensory, electrophysiological, and structural outcomes comparable to ANG, with superior muscle preservation, supporting further investigation of AGRG as an autograft-sparing strategy.

Abstract

BACKGROUND: Peripheral nerve injuries remain challenging in reconstructive surgery. Autologous nerve grafting (ANG) is standard but limited by donor-site morbidity and graft availability. The antigliotic guiding regenerative gel (AGRG) matrix is a bioengineered hydrogel delivered within collagen conduits. This randomized controlled study compares AGRG, ANG, and empty conduits in a rat sciatic nerve gap model. METHODS: Thirty-nine female Sprague-Dawley rats (10-12 wk old, 250-300 g) underwent 15-mm sciatic nerve gap creation and were allocated to intact controls (n = 5), ANG (n = 12), NeuraGen conduit alone (n = 11), or conduit plus AGRG (n = 11). Assessments at 1, 2.5, and 4 months included von Frey thresholds, compound muscle action potential (CMAP) latency and amplitude, and semiquantitative histology for myelination, neuromuscular junctions, and gastrocnemius atrophy, graded 0 (normal morphology) to 4 (severe atrophy) on an established, standardized histopathological severity scale. RESULTS: At 4 months, von Frey thresholds were higher in AGRG (7.00 ± 0.45 g) than in ANG (4.67 ± 0.45 g; P < 0.0001) and conduit alone. CMAP latency remained low in AGRG; amplitude was greatest in ANG and intermediate in AGRG. Myelination and neuromuscular junction scores in AGRG and ANG indicated better outcomes than those in the conduit-alone group scores, and muscle atrophy was markedly reduced in AGRG (0.50 ± 0.50) versus ANG (3.00 ± 0.00) and conduit alone (4.00 ± 0.00; P < 0.01). CONCLUSIONS: AGRG-filled collagen conduits achieved sensory, electrophysiological, and structural outcomes comparable to ANG, with superior muscle preservation, supporting further investigation of AGRG as an autograft-sparing strategy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Next-generation Antigliotic Guiding Regenerative Gel Matrix (LDP-916) for Peripheral Nerve Reconstruction — Science Skim