Key points
From the paper's conclusion- GEM electrocautery and conventional scalpel incisions achieved comparable long-term scar outcomes. Although GEM was associated with modest improvements in intraoperative parameters, the clinical significance of these differences should be interpreted in the context of the higher cost of the device.
Abstract
BACKGROUND: Postoperative scarring is an important concern following thyroid and parathyroid surgery. Geometric electron modulation (GEM) electrocautery is designed to reduce tissue injury while providing effective hemostasis. However, evidence regarding its long-term cosmetic outcomes remains limited. This study compares long-term scar quality following cervical incisions created using GEM electrocautery versus a conventional scalpel. METHODS: In this prospective, randomized, self-controlled trial, 24 patients undergoing thyroidectomy or parathyroidectomy were enrolled. Each half of the cervical incision was randomly assigned to GEM electrocautery or conventional scalpel. Intraoperative blood loss, incision time, and surgical field clarity were recorded. Scar quality was assessed at 2 weeks and at 1, 3, and 12 months using the Thai linear version of the Patient and Observer Scar Assessment Scale. Longitudinal analyses were performed using generalized estimating equations. RESULTS: Patient-reported Patient and Observer Scar Assessment Scale scores were significantly lower in the GEM group at 1 month (P = 0.02), with no differences at other follow-up visits. Observer-reported scores did not differ significantly at any time point. Longitudinal analyses demonstrated no significant differences in patient- or observer-reported scar outcomes between groups (generalized estimating equation P = 0.69 and 0.67, respectively). GEM electrocautery was associated with lower measured blood loss and a shorter incision time (both P < 0.01). CONCLUSIONS: GEM electrocautery and conventional scalpel incisions achieved comparable long-term scar outcomes. Although GEM was associated with modest improvements in intraoperative parameters, the clinical significance of these differences should be interpreted in the context of the higher cost of the device.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative efficacy of various wound dressings on scar formation following thyroidectomy: a systematic review and meta-analysis.Journal of comparative effectiveness research · 2026
- Early scar-directed interventions for thyroidectomy scars: a systematic review and network meta-analysis.Frontiers in surgery · 2026
- Scar Assessment Between Lateral Approach and Conventional Thyroidectomy.Clinical otolaryngology : official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-Laryngology & Cervico-Facial Surgery · 2026
- Gasless endoscopic thyroidectomy via the transsubclavian approach: comparable safety and superior anterior cervical function preservation.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Safety, short-term patient-reported outcomes, and cosmetic satisfaction of gasless transaxillary endoscopic thyroidectomy: a retrospective analysis of 530 patients.Frontiers in endocrinology · 2026
- Association of combined near-infrared autofluorescence and indocyanine green angiography with immediate and permanent postoperative hypoparathyroidism after thyroid surgery: a propensity score-matched analysis.Updates in surgery · 2026