Robotic Versus Endoscopic Approach in Single-port Nipple-sparing Mastectomy With Direct-to-implant Prepectoral Breast Reconstruction.
Mengxin Li, Guangqian Shen, Shan Li, Hongchuan Jiang, Ren Lang, Zihan Wang
From the Division of Breast Surgery, Department of General Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China. · Division of Hepatobiliary and Pancreatic Surgery, Department of General Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China.
Key points
From the paper's conclusion- Robot-assisted nipple-sparing mastectomy with direct-to-implant prepectoral reconstruction is currently associated with longer operative time and higher cost compared with the endoscopic approach. Larger prospective studies with extended follow-up are needed to assess its oncological safety and aesthetic outcomes.
Abstract
BACKGROUND: This study compares surgical and implant-related outcomes between robotic and endoscopic approaches in single-port nipple-sparing mastectomy with direct-to-implant prepectoral breast reconstruction. METHODS: In this retrospective cohort study, 54 patients undergoing nipple-sparing mastectomy with prepectoral reconstruction were divided into a robotic group (n = 21) and an endoscopic group (n = 33). Perioperative variables, including operative time, blood loss, drainage duration, hospital stay, and costs, as well as postoperative complications, were analyzed and compared between the 2 groups. RESULTS: Median follow-up was 4.45 months for the robotic group and 8.73 months for the endoscopic group. The robotic approach required significantly longer operative time (244.32 ± 43.10 versus 178.72 ± 47.53 min, P < 0.001) and incurred substantially higher cost (US $14,464.77 ± $503.38 versus $10,303.79 ± $1017.26, P < 0.001). No significant differences were observed in intraoperative blood loss, length of hospital stay, drainage duration, or postoperative complication rates between the 2 groups. CONCLUSIONS: Robot-assisted nipple-sparing mastectomy with direct-to-implant prepectoral reconstruction is currently associated with longer operative time and higher cost compared with the endoscopic approach. Larger prospective studies with extended follow-up are needed to assess its oncological safety and aesthetic outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative analysis of robotic- and endoscopic-assisted minimally invasive nipple-areola complex-sparing mastectomy for breast cancer: a meta-analysis with subgroup analyses.Journal of robotic surgery · 2026
- Robotic nipple-sparing mastectomy in breast cancer: current evidence, technical considerations, and clinical outcomes.Updates in surgery · 2026
- Minimally Invasive Nipple-Sparing Mastectomy: Early Experience With Endoscopic and Robotic TechniquesEuropean Journal of Breast Health · 2026
- Single-port robot-assisted nipple-sparing mastectomy: a systematic review.Journal of robotic surgery · 2026
- Long-term oncologic outcomes of minimal access (endoscopic- or robotic-assisted) nipple-sparing mastectomy compared with conventional approach in breast cancer: a propensity score matching analysisInternational Journal of Surgery · 2025
- Single‑port endoscopic nipple-sparing mastectomy combined with prosthesis breast reconstruction in breast cancer: a retrospective single-center study of 167 casesWorld Journal of Surgical Oncology · 2026