Quantification of Upadacitinib, Dasatinib, Ruxolitinib, Imatinib, and Cabozantinib in Plasma With Liquid Chromatography-Tandem Mass Spectrometry.
Mohsin El Amrani, Pim M A Keur, Kim C M van der Elst, Bognàr Tim
Department of Clinical Pharmacy, Division of Laboratory, Pharmacy and Biomedical Genetics University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.
Key points
From the paper's conclusion- This simple, rapid, sensitive, and robust LC-MS/MS method enables simultaneous quantification of 5 TKIs at different concentrations with minimal sample volume and excellent analytical performance, supporting its use in therapeutic drug monitoring and pharmacokinetic studies of kinase inhibitors in clinical practice.
Abstract
BACKGROUND: Tyrosine kinase inhibitors (TKIs) are increasingly used to treat hematological malignancies and solid tumors. As pharmacokinetic variability is substantial among patients, therapeutic drug monitoring may help optimize treatment efficacy and minimize toxicity. However, simultaneous quantification of multiple TKIs with markedly different therapeutic concentration ranges is challenging. A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous quantification of upadacitinib, dasatinib, ruxolitinib, imatinib, and cabozantinib in human plasma. METHODS: Proteins were precipitated in methanol containing stable isotope-labeled internal standards. Rapid chromatographic separation (5 minutes) was achieved on a BEH C18 column using a gradient of 0.025% ammonium hydroxide in water and methanol. TKIs were detected using a triple-quadrupole mass spectrometry in positive electrospray ionization mode. EMA ICH M10 guidelines were used for method validation. RESULTS: All analytes showed excellent linearity (R2 ≥ 0.9992) over calibration ranges of 0.1-10,000 mcg/L depending on the analyte. Lower limits of quantification were 0.1 mcg/L for upadacitinib and dasatinib, 0.5 mcg/L for ruxolitinib, 2.25 mcg/L for cabozantinib, and 10 mcg/L for imatinib. Within-run and between-run precision were ≤4.7% and ≤3.1%, respectively, and accuracy ranged from 0.1% to 13.2%. No significant matrix effects, carryover, or interference were observed. All analytes were stable during short-term storage (3 days at 5°C and 20°C), freeze-thaw cycles, and long-term storage (12 months at -20°C and -80°C). CONCLUSIONS: This simple, rapid, sensitive, and robust LC-MS/MS method enables simultaneous quantification of 5 TKIs at different concentrations with minimal sample volume and excellent analytical performance, supporting its use in therapeutic drug monitoring and pharmacokinetic studies of kinase inhibitors in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- HPLC-MS Quantification of Multiple Tyrosine Kinase Inhibitors in Patients with Solid Tumors: Method Validation and Clinical Application.Pharmaceutics · 2026
- Development and Validation of an LC-MS/MS Method for Simultaneous Quantification of Pazopanib, Cabozantinib, Sorafenib, Axitinib, Tivozanib, Sunitinib, and the Metabolites Sorafenib N-Oxide and Desethyl-Sunitinib in Human Plasma.Pharmaceuticals (Basel, Switzerland) · 2026
- Capillary dried plasma microsampling: A novel approach for therapeutic drug monitoring of tyrosine kinase inhibitors in chronic myeloid leukemia patients by UPLC-MS/MS.Journal of pharmaceutical and biomedical analysis · 2026
- Simultaneous LC-MS/MS quantification of four KRAS inhibitors (RMC-6236, RMC-9805, RMC-7977, and MRTX1133) in human plasma: toward therapeutic drug monitoring in pancreatic ductal adenocarcinoma.Bioanalysis · 2026
- Target Attainment and Clinical and Biochemical Parameters Associated with the Pharmacokinetics of 12 Tyrosine Kinase Inhibitors.Clinical pharmacokinetics · 2026
- High-throughput UHPLC-MS/MS Assay for the Quantification of Venetoclax in Patients with Acute Myeloid Leukemia and Assessment of Clinical Application: A Short CommunicationTherapeutic Drug Monitoring · 2026