Picosecond 755-nm Alexandrite Laser for Cutaneous Siderosis.
Xiaozhun Hang, Davin Sui Lim, Philip Bekhor, Angus Collins
Mowbray Park Medical and Dermatology, Brisbane, QLD, Australia.
Key points
From the paper's conclusion- The 755-nm picosecond alexandrite laser achieved substantial clearance of cutaneous siderosis with minimal transient adverse effects in this small case series. Histologic demonstration of iron deposition extending to approximately 4.1 mm provides clinicopathologic support for a depth-based approach to wavelength selection. Further studies are required to determine the role of pigment-depth assessment in guiding laser treatment.
Abstract
BACKGROUND: Optimal wavelength selection for laser treatment of cutaneous siderosis remains uncertain. The 755-nm picosecond alexandrite laser permits relatively deep dermal penetration, but clinicopathologic correlation between iron deposition depth and wavelength selection has not been well described. OBJECTIVE: To describe the clinical response and safety of 755-nm picosecond alexandrite laser treatment for cutaneous siderosis and examine the clinicopathologic relationship between iron deposition depth and wavelength selection. PATIENTS AND METHODS/MATERIALS: Three women aged 36 to 44 years with Fitzpatrick skin types I to II and persistent cutaneous siderosis after intravenous iron infusion were treated with a 755-nm picosecond alexandrite laser using a 3.1- to 4.0-mm spot size, fluence of 1.8 to 3.3 J/cm2, and frequency of 5 to 10 Hz at 5- to 6-week intervals. Treatment was end point driven, targeting tissue graying and mild edema. Clinical response was assessed by serial photography. Histopathologic examination in 1 patient demonstrated hemosiderin extending from the superficial dermis into the subcutaneous tissue. RESULTS: All 3 patients achieved greater than 75% clearance after 5 to 8 treatment sessions. Mild transient adverse effects included focal scabbing in 1 patient and pinpoint bleeding in another. Both resolved without scarring, dyspigmentation, or other sequelae. CONCLUSION: The 755-nm picosecond alexandrite laser achieved substantial clearance of cutaneous siderosis with minimal transient adverse effects in this small case series. Histologic demonstration of iron deposition extending to approximately 4.1 mm provides clinicopathologic support for a depth-based approach to wavelength selection. Further studies are required to determine the role of pigment-depth assessment in guiding laser treatment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Efficacy and Safety of 755‐nm Picosecond Alexandrite Versus Q‐Switched Nd:YAG Lasers for Nevus of Ota: A Systematic Review and Meta‐AnalysisDermatological Reviews · 2026
- Efficacy of 1064‐nm Picosecond Laser in the Treatment of Lichen Planus Pigmentosus: A Split‐Face Randomized Controlled TrialJournal of Cosmetic Dermatology · 2026
- A 520 ± 10 nm diode laser for the treatment of facial telangiectasiasLasers in Medical Science · 2026
- Use of a nanosecond Q-switched 1064 nm Nd: YAG laser for photoaging management in Asian skin: a retrospective study.Lasers in medical science · 2026
- Clinical Efficacy and Histologic Correlation of a High-Powered 675-nm Non-Ablative Diode Laser for Facial Rejuvenation.Lasers in surgery and medicine · 2026
- Efficacy and Safety of 755-nm Picosecond Alexandrite Laser for Acquired Bilateral Naevus of Ota-Like Macules (Hori Naevus): A Systematic Review and Meta-Analysis.The Australasian journal of dermatology · 2026