Drug-Coated Balloons Versus Drug-Eluting Stents in Patients With Chronic Kidney Disease Undergoing Percutaneous Coronary Intervention: A Systematic Review and Meta-Analysis With Reconstructed Individual Patient Data and GRADE Assessment.
Ahmed Mohamed Elbeny, Mohamed Hamouda Elkasaby, Waseem Omar Ahmed, Muhammad Abdullah Abdelsalm Othman, Mohammed Ahmed Ezzat, Abdelrahman Mohamad Sabry Elhadary, Abdelaal Alsayed Abdelrahman Alkhouly, Karim Mashhour,
From the Department of Cardiology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt. · Department of Medicine, Faculty of Medicine, Al-Azhar University, Cairo, Egypt.
Key points
From the paper's conclusion- We searched PubMed, Embase, Scopus, and Web of Science through May 2026 for studies comparing DCB with drug-eluting stents (DES) in adults with CKD undergoing PCI.
Abstract
Patients with chronic kidney disease (CKD) undergoing percutaneous coronary intervention (PCI) face high ischemic and bleeding risks. Drug-coated balloons (DCB) avoid a permanent implant and permit shorter dual antiplatelet therapy. We searched PubMed, Embase, Scopus, and Web of Science through May 2026 for studies comparing DCB with drug-eluting stents (DES) in adults with CKD undergoing PCI. Study-level hazard ratios (HRs) were pooled with random-effects inverse-variance models; individual patient data (IPD) were reconstructed from published Kaplan-Meier curves, and certainty was rated with Grading of Recommendations Assessment, Development and Evaluation. Five studies (two prespecified CKD analyses of randomized trials and three cohorts) comprising 2527 patients (1149 DCB and 1378 DES) were included. DCB and DES did not differ in the composite of major adverse cardiovascular or device-oriented events [HR 0.98; 95% confidence interval (CI), 0.77-1.24; IPD HR 0.96; 95% CI, 0.74-1.25], target-lesion revascularization (HR 1.02; 95% CI, 0.73-1.42), cardiac death (HR 0.94; 95% CI, 0.64-1.39), or myocardial infarction (HR 0.62; 95% CI, 0.36-1.06). Major bleeding did not differ significantly (HR 0.39; 95% CI, 0.13-1.17; IPD HR 0.51; 95% CI, 0.25-1.02). Stent or lesion thrombosis occurred only after DES (0/594 vs 12/810). Certainty was moderate for the composite endpoint and low for other outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Chronic Kidney Disease on Outcomes After Paclitaxel-Coated Balloon Angioplasty for Coronary In-Stent Restenosis.Circulation. Cardiovascular interventions · 2026
- Drug-coated balloons versus drug-eluting stents following coronary atherectomy in severely calcified lesions: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Drug-coated balloons versus drug-eluting stents in acute coronary syndrome: A meta-analysis of randomized controlled trialsTzu Chi Medical Journal · 2026
- Drug-Coated Balloon-Based Versus Drug-Eluting Stent-Only Strategy in Stable Angina and Acute Coronary Syndrome: A Propensity-Score Overlap-Weighted Analysis.Journal of clinical medicine · 2026
- Drug-Coated Balloons in De Novo Large and Small Vessels: A State-of-the-Art Review.Journal of the Society for Cardiovascular Angiography & Interventions · 2026
- Drug-Coated Balloons in Acute Coronary Syndromes: A Systematic Review.Journal of the Society for Cardiovascular Angiography & Interventions · 2026