Development and temporal validation of a proof-of-concept artificial intelligence model for binary classification of cervical cotest.
Valentina Chiappa, Carlotta Caia, Matteo Interlenghi, Biagio Paolini, Simona Palladino, Diletta Costeniero, Marzia Mietta, Francesco Raspagliesi,
Department of Gynecologic Oncology, Fondazione IRCCS Istituto Nazionale dei Tumori di Milano. · Department of Clinical Sciences and Community Health, Università degli Studi di Milano.
Key points
From the paper's conclusion- The model demonstrated high patch-level discriminative ability for the selected binary cotest classification.
Abstract
To develop and temporally validate a proof-of-concept deep learning model applied to digitized ThinPrep cervical cytology and human papillomavirus (HPV) cotest results for cervical dysplasia identification and triage support. This retrospective single-center study included women undergoing cervical cotesting at Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy, between January and September 2023 (development cohort January-July; temporal validation cohort August-September). The model distinguished true-negative cotest cases from HPV-positive low-grade/high-grade squamous intraepithelial lesions; atypical squamous cells of undetermined significance or cannot exclude high-grade lesion, glandular abnormalities, and invasive lesions were excluded. Two convolutional neural network architectures (ResNet50 and DenseNet201) were trained using transfer learning and evaluated by three-fold cross-validation. The best-performing model was validated on an independent temporal cohort (732 image patches; n = 63 women). ThinPrep slides from 337 women generated 3867 image patches for model development. All performance metrics are reported at the image-patch level and not at the patient level. The ResNet50 ensemble achieved the highest patch-level performance (area under the receiver operating characteristic curve: 96%) in temporal validation. At the optimized 30% threshold, sensitivity was 93%, negative predictive value 94%, and accuracy 89%. Reference cotest categories were significantly associated with colposcopic impression (P < 0.001) and histological outcome (P < 0.001 in the development cohort). The model demonstrated high patch-level discriminative ability for the selected binary cotest classification. Although these findings suggest a potential role for artificial intelligence-assisted cytology within screening programs, prospective multicenter studies with patient-level analysis are required before clinical implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Closing the Automation Gap in HPV-Based Cervical Cancer Screening: Independent External Validation of an AI Model for Dual-Stain Triage.NEJM AI · 2026
- Deep learning-assisted versus manual reading in routine cervical cytopathology: a multicentre randomised crossover trialnpj Digital Medicine · 2026
- Development of Cervical Cancer Diagnosis Tool From Histological and Colposcopy Images Using Multimodal Deep Learning Architecture: A Retrospective Dataset‐Based StudyHealth Science Reports · 2026
- CerviDBF-Net: Leveraging Spatial and Temporal Features for Accurate Cervical Cancer DiagnosisInternational Journal of Innovative Technology and Interdisciplinary Sciences · 2026
- Attention-Enhanced DenseNet Architecture for Robust Cervical Cytology ClassificationInternational Journal of Electronics and Telecommunications · 2026
- Deep Learning for Cervical Cytology Screening: Methods, Algorithms, Challenges and ProspectsarXiv · 2026